background image

500

Hz

500

Hz

500

Hz

.6

sec

.6

sec

.6

sec

A. Bong Alert Tone

B. Buzzer Alert Tone

E. Siren (Yelp)

S

S

o

o

u

u

n

n

d

d

O

O

u

u

t

t

p

p

u

u

t

t

S

S

p

p

e

e

c

c

i

i

f

f

i

i

c

c

a

a

t

t

i

i

o

o

n

n

s

s

On

Off

On

Off

On

Off

300 ms

300 ms

300 ms

280 Hz

2270 Hz

280 Hz

2270 Hz

3 sec

60 Hz

Single

.8 sec

60 Hz

Double

60 Hz

.8 sec

.8 sec

60

Hz

60

Hz

60

Hz

500 Hz

3 sec

500 Hz

3 sec

500 Hz

3 sec

1 sec

1 sec

1 sec

Single

Double

Triple

3 second break

then repeated

a second time

3 second break

then repeated

a second time

Continuously repeated while pin 11 is shorted to pin 12.

Triple

840 Hz

C. Doorbell (Ding Dong)

On

Off

.3 sec

3 sec

500 Hz

One per closure across pin 9 and pin 12.

D. Evacuation Signal (Temporal Slow Whoop)

On

Off

.5 sec

.5 sec

.5 sec

.5 sec

1.5 second

Break

200 Hz

700 Hz

Continuously repeated while pin 10 is shorted to pin 12.

.5 sec

7

Содержание CTG--1

Страница 1: ...audio output Non volatile programming memory Battery backup for maintaining clock time with factory installed 9V NiMh rechargeable battery Two sets of DPDT relay contacts for muting paging or backgro...

Страница 2: ...erence to radio communica tions Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own...

Страница 3: ...nt when reviewing programming Alert Tones Programming Buttons After setting an event time press SIN GLE DOUBLE or TRIPLE to program 1 2 or 3 alert bongs buzzer sounds for that event time Secondary But...

Страница 4: ...of Paging Amp or Common Siren Evacuation Signal Doorbell Dry Contact Closures from Alarm Equipment Doorbell Switch Etc I In ns st ta al ll la at ti io on n Step 1 Press the MODE button repeatedly unt...

Страница 5: ...ng the MODE button Step 1 Press the MODE button repeatedly until the SET EVENTS indicator lights Step 2 Increase or decrease the event time by pressing the TIME or CANCEL button until the desired time...

Страница 6: ...upport at 715 386 8666 J DIP Switch and Shunt Settings Internal View of the CTG 1 1 2 ON ON OFF 60 Hz installed 50 Hz removed Turn DIP switch 1 OFF Unplug the CTG 1 from power Pause a few seconds and...

Страница 7: ...z 60 Hz 60 Hz 500 Hz 3 sec 500 Hz 3 sec 500 Hz 3 sec 1 sec 1 sec 1 sec Single Double Triple 3 second break then repeated a second time 3 second break then repeated a second time Continuously repeated...

Страница 8: ...Ot th he er r A Ap pp pl li ic ca at ti io on ns s The store will be closing in 10 minutes Please bring all items to the check out or To Input of Paging Amplifier Model M15W shown not included Backgro...

Отзывы: