background image

42” min.

 

(106.7 cm)

13” max.

 

(

33.0 cm)

6” min.

(15.2 cm)

18” min.

(45.7 cm)

3/8”

 

(0.95 cm)

36” 

(91.4 cm)

29-7/8”

(75.9 cm)

A

Range

Width

“A”

Dimension

30”

30” (76.2 cm)

Clearance Dimensions 

(Proximity to Cabinets)

8

• This range may be installed directly adjacent

to existing 36” (91.4 cm) high base cabinets.

IMPORTANT:

The side trim MUST be 

3/8” (.95 cm) above the adjacent base
cabinet countertop. This can be
accomplished by raising the unit using 
the adjustment spindles on the legs.

• The range CANNOT be installed directly

adjacent to sidewalls, tall cabinets, tall
appliances, or other side vertical surfaces
above 36” (91.4 cm) high. There must be
a minimum of 6” (15.2 cm) side clearance
from the range to such combustible surfaces
above the 36” (91.4 cm) counter height.

• Within the 6” (15.2 cm) side clearance to

combustible vertical surfaces above 
36” (91.4 cm), the maximum wall cabinet
depth must be 13” (33.0 cm) and wall
cabinets within this 6” (15.2 cm) side
clearance must be 18” (45.7 cm) above
the 36” (91.4 cm) high countertop.

• Wall cabinets above the range must be a

minimum of 42” (106.7 cm) above the
range cooking surface for the full width 
of the range. This minimum height
requirement does not apply if a range
hood is installed over the cooking surface.

Note: 

If a range hood is installed, wall cabinets above the

range have a different minimum clearance height.

CAUTION

BURN HAZARD

To avoid risk of personal injury;
the use of cabinets for storage
above the appliance may result

in a potential burn hazard. Combustible
items may ignite, metallic items may
become hot and cause burns. If cabinet
storage is used, the risk can be reduced 
by installing a rangehood that projects
horizontally a minimum 5

(12.7 cm) beyond

the bottom of cabinets.

CAUTION

To prevent possible damage to cabinets
and cabinet finishes, use only materials
and finishes that will not discolor or
delaminate and will withstand temperatures
up to 194°F (90°C). Heat and moisture
resistant adhesive must be used if the
product is to be installed in laminated
cabinetry. Check with your builder or
cabinet supplier to make sure that the
materials meet these requirements.

Содержание CRVER

Страница 1: ...Installation 3 Series Freestanding 30 Electric Self Clean Range...

Страница 2: ..._______________________________________13 Leg Installation______________________________________________________________14 Electrical Connection 3 wire ________________________________________________...

Страница 3: ...y and the safety of others is very important We have provided many important safety messages in this manual and on your appliance ALWAYS read and obey all safety messages This is the safety alert symb...

Страница 4: ...spect to any significant sources of water or moisture Viking Range LLC will NOT warranty any problems resulting from GFI outlets which are not installed properly or do not meet the requirements below...

Страница 5: ...ommended WARNING TIPPING HAZARD THIS RANGE CAN TIP A CHILD OR ADULT CAN TIP THE RANGE AND BE KILLED FAILURE TO INSTALL THE ANTI TIP DEVICE CAN RESULT IN DEATH OR SERIOUS BURNS TO CHILDREN OR ADULTS IF...

Страница 6: ...8 91 1 cm min to 37 94 0 cm max RVER CRVER 35 7 8 91 1 cm min to 37 94 cm max 25 3 4 65 4 cm 45 114 3 cm 19 1 4 48 9 cm 24 61 0 cm 25 63 5 cm 29 73 7 cm 6 15 2 cm 25 63 5 cm 27 1 8 68 9 cm Note Unit...

Страница 7: ...2 000 watts 1 200 watts 3 200 watts 1 200 watts 2 000 watts Oven interior width 25 5 16 64 6 cm Oven interior height 16 1 2 41 9 cm Oven interior depth AHAM 16 13 16 42 7 cm Overall 19 1 2 49 5 cm Ov...

Страница 8: ...ve the 36 91 4 cm high countertop Wall cabinets above the range must be a minimum of 42 106 7 cm above the range cooking surface for the full width of the range This minimum height requirement does no...

Страница 9: ...9 cm 24 61 0 cm or 27 38 6 cm 30 76 2 cm 6 15 2 cm Wood Composite Overlay Wood Composite Overlay 30 min 76 2 cm to 36 max 91 4 cm 0 0 cm 30 min 76 2 cm to 36 max 91 4 cm Wall Installation Island Inst...

Страница 10: ...e required use of a GFI is normally related to the location of a receptacle with respect to any significant sources of water or moisture WARNING ELECTRICAL SHOCK HAZARD To avoid the risk of electrical...

Страница 11: ...11 Electrical Requirements Electric access area 6 15 2 cm 6 15 2 cm 4 3 8 4 3 8 11 1 cm 11 1 cm 4 3 8 11 1 cm 3 1 2 8 9 cm 3 7 6 cm REAR VIEW SIDE VIEW...

Страница 12: ...ion section Some stainless steel parts may have a plastic protective wrap which must be peeled off The interior should be washed thoroughly with hot soapy water to remove film residues and any dust or...

Страница 13: ...installation to ensure that it is not used to lift the unit DO NOT lift or carry the door by the handle Removing the door must be done by your dealer or a qualified licensed plumber Door Removal 1 Op...

Страница 14: ...re not secure for long transit Note It is strongly recommended that a pallet or lift jack be used rather than tilting Raise unit about a foot Unscrew temporary legs from couplings 4 Lower range gently...

Страница 15: ...ical shock personal injury or death verify your appliance has been properly grounded in accordance with local codes or in absence of codes with the National Electrical Code NEC ANSI NFPA 70 latest edi...

Страница 16: ...onnection Bare Wire Connection To make a bare wire connection use holes on the left side of the terminal block To connect eyelet style wires use holes on right side of terminal Push supply cord toward...

Страница 17: ...ELECTRICAL SHOCK HAZARD To avoid risk of electrical shock personal injury or death verify your appliance has been properly grounded in accordance with local codes or in absence of codes with the Natio...

Страница 18: ...white to center terminal on terminal block 1 3 7 1 2 8 Push supply cord toward terminal block to relieve strain reattach supply cord strain relief bracket over supply cord Reattach access door 1 1 Eye...

Страница 19: ...quired may exceed the thread available in the leg 3 3 8 3 8 0 95 cm 0 95 cm 3 8 0 95 cm 4 Move unit into opening Leveling Adjustments Alignment 5 Check that unit is level side to side and front to bac...

Страница 20: ...k of the appliance tipping it must be secured by a properly installed anti tip bracket s To make sure the bracket has been installed properly look behind the range with a flashlight to verify proper i...

Страница 21: ...rk and drill holes where bracket will be located 1 8 1 2 8 1 2 21 6 cm 21 6 cm 8 1 2 21 6 cm 1 8 1 8 32 cm 32 cm 1 8 32 cm 1 1 2 1 1 2 3 8 cm 3 8 cm 1 1 2 3 8 cm Locate anti tip bracket hook on the fl...

Страница 22: ...uirements section for more information Final Installation 2 Slide range into place Be sure anti tip bracket slides into the anit tip opening 2 1 x2 3 Remove two screws from back of range 1 2 4 Attach...

Страница 23: ...to back The side trim must be 3 8 0 95 cm above countertop If unit is not level repeat Steps 5 7 of Leveling Adjustments Alignment section 1 2 Carefully realign door on hinges Slide in and down Open...

Страница 24: ...pproximately 30 seconds the center and outside broil elements will turn on and the bake element will turn on at partial power Check broil elements through window to make sure they are on then abort se...

Страница 25: ...t if service is ever required Model number ____________________________________________________________________________________ Serial number __________________________________________________________...

Страница 26: ...________________________________________________________________________________________________________ _______________________________________________________________________________________________...

Страница 27: ...________________________________________________________________________________________________________ _______________________________________________________________________________________________...

Страница 28: ...e LLC 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit our website at vikingrange com in the US or brigade ca in Canada F21193A EN 100...

Отзывы: