background image

Cutout Dimensions

(36”W.)

10

11

Clearance Dimensions

36

” m

in.

(91

.4

cm

)*

13

” m

ax

.

(

33

.0

cm

)

6”

m

in.

(15

.2

cm

)**

18

” m

in.

(45

.7

cm

)

3-1

/8”

(7.9

cm

)

0”

min

.

(0.0

cm

)

36

” m

in.

(91

.4

cm

)

HO

T

RE

AR

FR

ON

T

HO

T

RE

AR

FR

ON

T

*Note:

36” minimum unless using a hood.

**Note:

Only applies to combustible surfaces.

Dimensions shown are for use with combustible
surfaces unless otherwise stated.

Proximity to Side Cabinet Installation

• The cooktop may be installed directly to exist-

ing base cabinets.

• The cooktop

CANNOT

be installed directly ad-

jacent to sidewalls, tall cabinets, tall appliances,
or other side vertical surfaces above 36” (91.4
cm) high. There must be a minimum of 6” (15.2
cm) side clearance from the cooktop to such
combustible surfaces above the 36” (91.4 cm)
counter height.

• Within the 6” (15.2 cm) side clearance to com-

bustible vertical surfaces above
36” (91.4 cm), the maximum wall cabinet depth
must be 13” (33.0 cm) and wall cabinets within
this 6” (15.2 cm) side clearance must be 18”
(45.7 cm) above the 36” (91.4 cm) high counter-
top.

• Wall cabinet above the cooktop

must be a minimum of 36” (91.4 cm)
above the countertop for a full width
of the cooktop.

Minimum Clearances from Adjacent Com-
bustible Construction

• Above countertop 36” (91.4 cm) minimum
• Side 6” (15.2 cm)
• Rear 0” (0.0 cm)
• Within 6” side clearance. Wall cabinets no

deeper than 13” (33.0 cm)

• Must be minimum 18” (45.7 cm) above coun-

tertop

• Wall cabinets directly above the product must

be minimum 36” (91.4 cm) above the counter-
top

36” W. CUTOUT w/
DOWNDRAFT

36” W. CUTOUT

19-1/8”

(48.6 cm) min.

19-7/8”

(50.5 cm) max.

34-9/16”

(87.8 cm) min.

35-1/2”

(90.2 cm) max.

20-1/4”

2-1/4”

7/8”

7/8”

34-3/4”

(88.3 cm)

(51.4 cm)

(5.7 cm)

(2.2 cm)

(2.2 cm)

33”

(83.8 cm)

Содержание Built-In Electric Induction/Radiant Cooktop

Страница 1: ...diant Cooktop Viking Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com...

Страница 2: ...warnings or plates from the product This may void the warranty Please observe all local and national codes and ordinances Please ensure that this product is properly grounded The installer must leave...

Страница 3: ...ppliance may result in potential burn haz ard Combustible items may ignite metallic items may become hot and cause burns If a cabinet storage is to pro vided the risk can be reduced by installing a ra...

Страница 4: ...40V 37 9 amps 9 1 kw 208V 35 4 amps 7 4 kw 240V 55 0 amps 13 2 kw 208V 50 2 amps 10 4 kw Surface element rating Right front Right rear Center front Bridge Center rear Left front Left rear 240V 208V 1...

Страница 5: ...e shelf underneath is 18 45 7 cm There should be no partition or shelf directly underneath the unit It is also required that the exit air ports at the rear are not blocked There should be a mini mum o...

Страница 6: ...36 91 4 cm counter height Within the 6 15 2 cm side clearance to com bustible vertical surfaces above 36 91 4 cm the maximum wall cabinet depth must be 13 33 0 cm and wall cabinets within this 6 15 2...

Страница 7: ...efer to the specifications chart for kilowatt rating and recommended amperage House wiring and fusing must comply with local codes If no local codes are applicable wire in accordance with the National...

Страница 8: ...g service on the cooktop DO NOT repair or replace any part of the appliance unless specifically recommended in the manual All other servicing should be referred to a qualified technician Contact Vikin...

Отзывы: