background image

8

9

Cutout Dimensions

(30”W.)

Cutout Dimensions

1”

(2.5

4 cm

)*

to

2-1

/2”

(6.3

5 cm

)*

19”

(48.8

cm

)

A

30”W. Models

36”W. Models

A

28-9/16”

(72.6 cm) min. to

29-5/8”

(75.2 cm) max.

34-9/16”

(87.8 cm) min. to

35-1/2”

(90.2 cm) max.

*Note:

Based on 24” deep cabinet with 3/4” backsplash.

18”

(45.7 cm) max.

8”

(20.3 cm) min.

1-1/4”

(3.2 cm) min.

Clearance Dimensions

Interior Cabinet Clearances

IMPORTANT:

The electronic components for

the induction elements in the cooktop need air
circulation. To ensure long life of electronic
components, it is required that a minimum of 8”
(3.8 cm) open space remain between the bot-
tom of the cooktop and any shelf underneath.
The maximum length of the shelf underneath is
18” (45.7 cm). There should be no partition or
shelf

directly

underneath the unit.

It is also required that the exit air ports at the
rear are not blocked. There should be a mini-
mum of 1-1/4” (3.2 cm) space between the exit
air ports at the rear of the unit and any nearby
obstruction, including downdrafts.

Note:

Before cutting countertop cutout, check

the inside clearance available from the inside

back wall to the proposed placement of the

cooktop. A minimum of 1-1/4” (3.2 cm) is re-

quired from the back wall of the cooktop to

the

inside

wall of the back cabinet. This may

require a distance greater than the 0” mini-

mum approved distance.

(5.7 cm)

7/8”

30” W. CUTOUT w/
DOWNDRAFT

28-3/4”

(73.0 cm)

20-1/4”

(51.4 cm)

2-1/4”

(2.2 cm)

7/8”

(2.2 cm)

27”

(68.6 cm)

30” W. CUTOUT

19-1/8”

(48.6 cm) min.

19-7/8”

(50.5 cm) max.

28-9/16”

(72.6 cm) min.

29-5/8”

(75.2 cm) max.

Содержание Built-In Electric Induction/Radiant Cooktop

Страница 1: ...diant Cooktop Viking Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com...

Страница 2: ...warnings or plates from the product This may void the warranty Please observe all local and national codes and ordinances Please ensure that this product is properly grounded The installer must leave...

Страница 3: ...ppliance may result in potential burn haz ard Combustible items may ignite metallic items may become hot and cause burns If a cabinet storage is to pro vided the risk can be reduced by installing a ra...

Страница 4: ...40V 37 9 amps 9 1 kw 208V 35 4 amps 7 4 kw 240V 55 0 amps 13 2 kw 208V 50 2 amps 10 4 kw Surface element rating Right front Right rear Center front Bridge Center rear Left front Left rear 240V 208V 1...

Страница 5: ...e shelf underneath is 18 45 7 cm There should be no partition or shelf directly underneath the unit It is also required that the exit air ports at the rear are not blocked There should be a mini mum o...

Страница 6: ...36 91 4 cm counter height Within the 6 15 2 cm side clearance to com bustible vertical surfaces above 36 91 4 cm the maximum wall cabinet depth must be 13 33 0 cm and wall cabinets within this 6 15 2...

Страница 7: ...efer to the specifications chart for kilowatt rating and recommended amperage House wiring and fusing must comply with local codes If no local codes are applicable wire in accordance with the National...

Страница 8: ...g service on the cooktop DO NOT repair or replace any part of the appliance unless specifically recommended in the manual All other servicing should be referred to a qualified technician Contact Vikin...

Отзывы: