12. Standard or Polycom Multicast Paging

Standard 

When using standard Multicast Paging, up to 10 multicast paging groups can be programmed into each 

300-IP

 paging 

horn. Each multicast group is defined by a multicast address and port number. Each multicast group is assigned a 
priority, allowing simultaneously arriving pages to be serviced based on importance. A timeout check box can be 
selected for each paging group. See Multicast Page Timeout under Paging Settings to adjust the timeout from 1 - 255 
seconds. Only one timeout time can be programmed for all groups. The volume for each multicast group can be 
programmed separately. 

Assigning Priority to standard Multicast Paging

 

The 

300-IP

 will prioritize simultaneous audio streams according to their priority in the Paging Sources list. Group 0 will 

have the highest priority while group 9 will have the lowest priority. Group 9 is useful for a low priority stream such as 
background music. Group 0 is useful for high priority streams such as emergency messages.  
The multicast paging groups can also be used for up to ten different paging zones for receiving audio streams. A paging 
zone can consist of one or many 

300-IP

 multicast paging horn. There is no limit to how many speakers can be in a 

given paging zone. Each multicast group is defined by a multicast address and port number. Each multicast group is 
assigned a priority, allowing simultaneously arriving pages to be serviced based on importance.  

Polycom  

Polycom IP phones send multicast audio to a specific IP address and port. A total of 25 groups can be used, with 
group 25 generally reserved for an emergency broadcast. Set the Multicast Page Type to “Polycom”.  The Viking IP 
programming page will then show “Polycom Paging Source and Group Subscriptions”.  Polycom phones will default 
to IP address 224.0.1.116 and port 5001 for multicast.  Under “Polycom Paging Source and Group Subscriptions”, 
enter the IP address and port you chose in the Polycom IP phone as “Multicast IP address” and “port” (Paging/PTT 
Configuration page).  Select the paging groups the 

300-IP

 should subscribe to.  Any multicast audio sent to the 

correct IP address, port number and a subscribed group will be heard from the Speaker terminals.  Group 1 is the 
lowest priority and group 25 is the highest.  The Volume and Timeout can be selected globally, although the timeout 
does not affect group 25.  

Factory Setting:

  all Groups selected 

The volume of each individual standard multicast page can be adjusted from 0 - 19.  When polycom paging is used, 
the paging volume is set globally for all 25 groups. 

Factory Setting:

  1  

13. Multicast Paging Volume

Содержание 300-IP

Страница 1: ...pliance IEEE 802 3 af PoE SIP 2 0 RFC3261 100BASE TX with auto cross over Regulatory Compliance CE FCC Part 15 and Canada ICES 003 Class A Maximum Output Level 113 dB SPL 1M Amplifier 6 Watt class D C...

Страница 2: ...to www vikingelectronics com and enter 944 in the search box 2 Click Application Note DOD 944 to open and download the PDF Scan the QR code below to open and download the Viking VoIP SIP System Compat...

Страница 3: ...tocol is an Internet protocol standard that specifies a way for programs to manage the real time transmission of multimedia data over either unicast or multicast network services Server A computer or...

Страница 4: ...he correct IP address Back View PoE LAN Port 10 100 PoE Class 3 13 Watts Connect to your LAN via RJ45 plug and CAT5 or greater twisted pair wire Red Call Status LED Flashes when unit is not registered...

Страница 5: ...tep 4 With both wing nuts loose rotate and angle the horn into position then tighten both wing nuts to secure Round Mounting Plate Base Screws not included 4 0 217 diameter 1 99 3 26 1 99 Mounting Pla...

Страница 6: ...ps 1 Gbps network speed for other equipment on network Available LAN with PoE class 3 13 Watts Ethernet cable CAT5 minimum 1 MB minimum free hard drive space for installation 16MB of free physical RAM...

Страница 7: ...how you each 300 IP speaker that is connected to that LAN Select the unit with the same MAC address shown on the label located next to the Ethernet connector on the 300 IP speaker Step 3 Click on the...

Страница 8: ...ecting an integer 1 to PSA 94 in ID for all packets Step 4 Set the Priority Code Point PCP value for all not SIP and RTP packets in the PCP for all packets input 0 is default priorities are from low t...

Страница 9: ...t for 6 seconds 4 beeps then light steady indicating when to remove the short across the Reset wires Step 4 You can now enter programming by following the steps in section A Programming Features Index...

Страница 10: ...unit name can be assigned to the 300 IP being programmed Programming Features Enter the IP address or URL of your SIP server or service provider in this field The SIP server IP address is limited to...

Страница 11: ...tory Setting Standard shown above 9 Pre Page Tone When enabled a short beep will be heard prior to SIP or Multicast paging audio The volume of the Pre Page Alert Tone will match the volume setting of...

Страница 12: ...SIP Page Priority Level can be set to Polycom or None See the following tables for the order of priorities with each setting As shown Polycom Group 25 multicast is the highest priority The priority o...

Страница 13: ...s no limit to how many speakers can be in a given paging zone Each multicast group is defined by a multicast address and port number Each multicast group is assigned a priority allowing simultaneously...

Страница 14: ...alls are handled NOTE For timed Night Ringing the unit must be synced with a time server If the Night Ringing feature is enabled in the software you will be asked to use Viking Time Server when change...

Страница 15: ...Viking model SL 2 strobe light etc Ring Flash Mode When programmed for Ring Flash Mode the relay will momentarily turn on and off in a 400 ms on off cadence while the ringing extension is called This...

Страница 16: ...dles incoming SIP calls One option is to generate a loud ring sound through the speaker The 300 IP can also auto answer a SIP call to transmit a page or control the relay The secure options for auto a...

Страница 17: ...ent cadences Factory Setting Normal Ring Normal Ring single ring 2 seconds ON 4 seconds OFF Double Ring double ring 1 second ON 0 5 second OFF 1 second ON 3 5 seconds OFF Short Short Long triple ring...

Страница 18: ...Clear Speaker Settings button in programming will reset all of the Programming Features back to their factory default settings NOTE This command will not change or reset your IP settings 34 Clear Spe...

Страница 19: ...Type to Polycom Standard Multicast Paging Factory Setting Up to 10 multicast paging groups can be programmed into each unit and each group is assigned a priority level allowing simultaneous arriving m...

Страница 20: ...IP call when the Inbound Call Mode is set to auto answer After the unit auto answers the call one beep will be heard if Pre Page Alert Tone is enabled If the Access Code has been disabled you can now...

Страница 21: ...Contacts 5A 30VDC 250VAC max Connect to Doorstrike Mag Lock Gate Controller etc 2 Gel Filled Butt Connectors included Doorstrike Magnetic Lock 120V AC Door near Speaker 4 1 IN1 C IN2 IN3 C IN4 2 3 4 5...

Страница 22: ...onal analog speakers The LED on the 40 IP can be programmed to light during paging For more info see DOD 503 40 IP IP Speaker for SIP Endpoint Paging SIP Multicast Paging Adapter The Viking model 40TB...

Страница 23: ...PA 250 IP SIP Multicast Paging Amplifier provides up to 250 Watts of loud paging for SIP based VoIP phone systems hardware or hosted cloud based service provider The PA 250 IP can be used for standard...

Страница 24: ...for diagnosis 2 If the Technical Support Product Specialist determines that the equipment is defective based on the customer s input and troubleshooting a Return Authorization RA number will be issue...

Отзывы: