background image

4

E

5

EXhAuST DuCT ASSEMBLY:

 Remove the cushions from the adhesive 

backing. The cushion should be applied to the flanges of the duct 

assembly as indicated by arrows. See figure 

5

a.

5

B

EXhAuST DuCT ASSEMBLY:

 Remove SCREw from the upper right 

and left corners at the rear of the oven. Place duct assembly on the 

top of the unit as shown and secure the duct assembly to the oven 

using the two screws just removed from the oven. See figure 

5

B.

*figures 

2

 - 

5

 for models vmTk277, 307 and 367 

ONLY

.

MOuNTINg TEMPLATE: 

Identify the appropriate side of template 

to use with your unit. align the mounting template center line with 

the center of the cutout and the floor line with the floor of the cutout. 

Tape it into place. 

• for vmTk272 only, predrill

4 holes marked “a” with a

1/16" drill bit.

• for vmTk277 only, predrill

4 holes marked “a” with a

1/16" drill bit.

• for vmTk302 only, predrill

4 holes marked “B” with a

1/16" drill bit.

• for vmTk307 only, predrill

4 holes marked “B” with a

1/16" drill bit.

• for vmTk362 only, predrill

4 holes marked “C” with a

1/16" drill bit.

• for vmTk367 only, predrill

4 holes marked “C” with a

1/16" drill bit.

Remove template from the cabinet.

A

Exhaust Duct Assembly

Surface Installation

6

NOTE:

 CENTER 

BOTTOm DUCT 

aSSEmBLy IN THE 

OPENING

DETAIL A

GaP "B"

BOTTOM DUCT ASSEMBLY

SCREW C

BOTTOM DuCT ASSEMBLY: 

Place the Bottom Duct in the center of 

the opening so that gap "a" is equal to gap "B". 

1

 when the Bottom 

Duct assembly for vmTk277SS, 307SS or 376SS is positioned properly, 

the front edge of the duct will be flush with the front of the cabinet. 

2

 The vmTk272SS, 302SS, 372SS Exhaust Duct will be positioned 

properly when the edge of the duct is recessed 5mm from the front 

of the cabinet. See figure 

6

. Secure the Bottom Duct assembly with 

the two (¾") SCREwS (C).

7

CABINET INSTALLATION: 

Place  the  oven  adjacent  to  the  wall  or 

cabinet  opening.  Plug  the  power  cord  into  the  electrical  outlet. 

Carefully guide the assembled oven into the prepared opening. Slide 

the oven on the Bottom Duct assembly. See figure 

7

SCREw

GaP "a"

Содержание VMTK272

Страница 1: ...Installation Guide Microwave Built In Trim Kit VMTK272 VMTK302 VMTK362 VMTK277 VMTK307 VMTK367 ...

Страница 2: ... microwave oven from the electrical outlet before installing the built in trim kit Remove the turntable from the oven cavity Because the kit includes metal parts caution should be used in handling and installation to avoid the possibility of injury Do not remove permanently affixed labels warnings or plates from the product This may void the warranty Please observe all local and national codes and...

Страница 3: ... Maximum Amp Usage 1 55 KW 1 5 KW 13 amps UL 13 CSA N A Approximate Shipping Wt 60 lbs 27 2 kg 19 lbs 8 6 kg 20 lbs 9 1 kg 23 lbs 10 5 kg Description CONVENTIONAL VMOS201 CVMOS201 VMTK272 VMTK302 VMTK362 Overall Width 24 60 9 cm 26 1 2 67 3 cm 29 1 2 74 9 cm 35 1 4 89 5 cm Overall Height from Bottom 13 3 8 33 9 cm 18 1 4 46 3 cm 18 1 4 46 3 cm 18 1 4 46 3 cm Overall Depth from Rear 19 1 4 48 9 cm ...

Страница 4: ...6 62 7 cm C Depth Min 20 1 8 51 1 cm Min 20 1 8 51 1 cm D Min Max 6 11 1 2 15 2 cm 29 2 cm E Min Max 4 5 10 2 cm 12 7 cm ELECTRICAL OUTLET LOCATION Outlet should NOT be in the shaded area as indicated on figure 1 At the rear of the opening provide a 3 pronged polarized electrical outlet 115 120 volt AC 15 amp or larger 2 DUCT C DUCT B SCREW A EXHAUST DUCT ASSEMBLY Insert the edge of DUCT B into th...

Страница 5: ... bit For VMTK307 only predrill 4 holes marked B with a 1 16 drill bit For VMTK362 only predrill 4 holes marked C with a 1 16 drill bit For VMTK367 only predrill 4 holes marked C with a 1 16 drill bit Remove template from the cabinet A Exhaust Duct Assembly Surface Installation 6 NOTE Center Bottom Duct Assembly in the opening DETAIL A GAP B BOTTOM DUCT ASSEMBLY SCREW C BOTTOM DUCT ASSEMBLY Place t...

Страница 6: ...essory kit PURCHASED SEPARATELY 2 Stainless Steel Scoops 10 Stainless Machine Screws 1 Flush Mount Template 2 Side Trim See FLUSH MOUNT Template for additional installation instructions Flush Mount INSTALLATION Place the 2 Scoops on the back of the frame as shown and align the screw holes on the scoop with the tapped holes in the frame Secure the scoops to the frame using 6 of the machine screws p...

Страница 7: ...below are not to be installed above gas ovens VMTK272SS VMTK307SS VMTK362SS VMTK277SS VMTK302SS VMTK367SS Flush Mount Installation CONVECTION CONVENTIONAL 27 30 36 27 30 36 A Height 21 5 16 542 cm 21 5 16 542 cm 21 5 16 542 cm 19 7 8 504 cm 19 7 8 504 cm 19 7 8 504 cm B Width 26 15 16 68 3 cm 29 15 16 76 cm 35 5 8 90 4 cm 26 15 16 68 3 cm 29 15 16 76 cm 35 5 8 90 4 cm C Depth 22 1 16 56 1 cm 22 1 ...

Страница 8: ...Guide d installation Kit de garniture à encastrer pour four à micro ondes VMTK272 VMTK302 VMTK362 VMTK277 VMTK307 VMTK367 F ...

Страница 9: ... Minimum Cutout Opening Width 24 3 8 619 13 mm Maximum Cutout Opening Width 24 11 16 627 06 mm Minimum Cutout Opening Height 16 3 4 425 5 mm Maximum Cutout Opening Height 17 431 8 mm Maximum Height distance between holes 14 1 4 361 825 mm Distance between centerline to holes 12 13 16 324 65 mm Distance between holes A 25 9 16 649 3 mm Distance between centerline to holes 14 5 16 362 75 mm Distance...

Страница 10: ... O Ampèrage max 1 55 KW 1 5 KW 13 amps UL 13 CSA S O Poids approx à l expédition 60 lbs 27 2 kg 19 lbs 8 6 kg 20 lbs 9 1 kg 23 lbs 10 5 kg Descriptión TRADITIONNEL VMOS201 CVMOS201 VMTK272 VMTK302 VMTK362 Largeur hors tout 24 po 60 9 cm 26 1 2 po 67 3 cm 29 1 2 po 74 9 cm 35 1 4 po 89 5 cm Hauteur hors tout depuis le bas 13 3 8 po 33 9 cm 18 1 4 po 46 3 cm 18 1 4 po 46 3 cm 18 1 4 po 46 3 cm Profo...

Страница 11: ...1 cm D Min Max 6 po 11 1 2 po 15 2 cm 29 2 cm E Min Max 4 5 10 2 cm 12 7 cm Emplacement De La Prise Électrique La prise NE doit PAS se trouver dans l aire ombrée comme indiqué à schéma 1 À l arrière de l ouverture installer une prise électrique polarisée pour fiche à trois broches 115 120 volt CA 15 A ou plus 2 CONDUIT C CONDUIT B VIS A schéma schéma ENSEMBLE DU CONDUIT D ÉVACUATION Insérer le bor...

Страница 12: ... 6 mm Pour VMTK302 uniquement percer les 4 trous marqués B avec un foret de 1 16 po 1 6 mm Pour VMTK307 uniquement percer les 4 trous marqués B avec un foret de 1 16 po 1 6 mm Pour VMTK362 uniquement percer les 4 trous marqués C avec un foret de 1 16 po 1 6 mm Pour VMTK367 uniquement percer les 4 trous marqués C avec un foret de 1 16 po 1 6 mm Enlever le gabarit de l armoire 6 REMARQUE ENSEMBLE DU...

Страница 13: ...ce que ses pattes entrent dans les évidements de l ENSEMBLE DU CONDUIT INFÉRIEUR Voir schéma 8 9 VIS B VIS B VIS B VIS B schéma schéma INSTALLATION DU CHÂSSIS Placer le CHÂSSIS ARRIÈRE pour qu il soit aligné avec les trous percés à l aide du gabarit Vérifier qu il est de niveau puis le fixer avec quatre VIS B Voir schéma 9 Fixer la partie inférieure de l ENSEMBLE DU CHÂSSIS avec deux VIS B restant...

Страница 14: ... Placer la décoration AVANT sur le CADRE et aligner les pivots à rotule avec les récepteurs Fixer la DÉCORATION sur le CADRE en poussant fermement le cadre avant sur le cadre arrière en engageant les quatre 4 fixations à pression Voir schéma Découpe pour le micro ondes Découpe du Four Inférieur schéma schéma INSTALLATION AU DESSUS D UN FOUR L espace entre les micro ondes et le four inférieur 5 08 ...

Страница 15: ...Instrucciones de Instalación Juego de Molduras para Empotrado para Horno Microondas VMTK272 VMTK302 VMTK362 VMTK277 VMTK307 VMTK367 S ...

Страница 16: ...4 3 8 619 13 mm Maximum Cutout Opening Width 24 11 16 627 06 mm Minimum Cutout Opening Height 16 3 4 425 5 mm Maximum Cutout Opening Height 17 431 8 mm Maximum Height distance between holes 14 1 4 361 825 mm Distance between centerline to holes 12 13 16 324 65 mm Distance between holes A 25 9 16 649 3 mm Distance between centerline to holes 14 5 16 362 75 mm Distance between holes B 28 9 16 725 5 ...

Страница 17: ...máx en amperios 1 55 KW 1 5 KW 13 amps UL 13 CSA N A Peso aproximado de embarque 60 lbs 27 2 kg 19 lbs 8 6 kg 20 lbs 9 1 kg 23 lbs 10 5 kg Descripción CONVENCIONAL VMOS201 CVMOS201 VMTK272 VMTK302 VMTK362 Ancho total 24 60 9 cm 26 1 2 67 3 cm 29 1 2 74 9 cm 35 1 4 89 5 cm Altura total desde la parte inferior 13 3 8 33 9 cm 18 1 4 46 3 cm 18 1 4 46 3 cm 18 1 4 46 3 cm Profundidad total desde la par...

Страница 18: ... 15 2 cm 29 2 cm E mín máx 4 5 10 2 cm 12 7 cm UBICACIÓN DEL TOMACORRIENTE ELÉCTRICO El tomacorriente NO debe estar en el área sombreada como se indica en la figura 1 En la parte posterior de la abertura debe haber un tomacorriente eléctrico de tres clavijas polarizado de 115 120 volt CA 15 amperios o mayor 2 DUCTO C DUCTO B TORNILLO A figura figura ENSAMBLAJE DEL DUCTO DE ESCAPE Inserte el extrem...

Страница 19: ...como B con una broca de 1 16 Sólo para VMTK307 taladre 4 agujeros marcados como B con una broca de 1 16 Sólo para VMTK362 taladre 4 agujeros marcados como C con una broca de 1 16 Sólo para VMTK367 taladre 4 agujeros marcados como C con una broca de 1 16 Retire la plantilla del gabinete 6 NOTA CENTRE EL CONJUNTO DEL DUCTO INFERIOR EN LA ABERTURA DETALLE A SEPARACIÓN B CONJUNTO DE DUCTO INFERIOR TOR...

Страница 20: ...e bolas 10 Tornillos inoxidables de máquina 1 Plantilla para montaje al ras 2 Molduras laterales Vea PLANTILLA DE MONTAJE AL RAS para instrucciones adicionales de instalación figura Instalación del montaje al ras Coloque las 2 paletas en la parte posterior del marco como se muestra en la imagen y alinee los agujeros de los tornillos de la paleta con los agujeros de colada del marco Asegure las pal...

Страница 21: ...uía de instalación y que se enumeran a continuación NO DEBEN SER INSTALADOS POR ENCIMA DE HORNOS A GAS VMTK272SS VMTK307SS VMTK362SS VMTK277SS VMTK302SS VMTK367SS CONVECCIÓN CONVENCIONAL 27 30 36 27 30 36 A Altura 21 5 16 542 cm 21 5 16 542 cm 21 5 16 542 cm 19 7 8 504 cm 19 7 8 504 cm 19 7 8 504 cm B Peso 26 15 16 68 3 cm 29 15 16 76 cm 35 5 8 90 4 cm 26 15 16 68 3 cm 29 15 16 76 cm 35 5 8 90 4 c...

Страница 22: ......

Страница 23: ......

Страница 24: ...TINSLB035MRR0 Viking Range LLC 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For more product information call 1 888 845 4641 ...

Отзывы: