manualshive.com logo in svg
background image

Specifications

7

Dimensions

6

Custom Gas 30” Rangetop

35-7

/8”

(91.1

cm

)

8-1/8”

(20.6 cm)

1-5/8”

(4.1 cm)

1”

(2.5 cm)

28-9/16”

(72.6 cm)

24-5/16”

(61.8 cm)

Note:

Unit shown with standard island trim.

29-7

/8”

(75.9

cm

)

Custom Gas 36” Rangetop

Minimum clearances from adjacent combustible construction

• Cooking surface and below, i.e., 36” (91.4 cm) and below

o Sides—0”
o Rear—0” with backguard or highshelf; 0” with island trim and noncombustible rear wall; 6” (15.2 cm) with island

trim and combustible rear wall.

• Above cooking surface, i.e. above 36" (91.4 cm)

o Sides—6” (15.2 cm)
o Within 6” (15.2 cm) side clearance, wall cabinets no deeper than 13” (33.0 cm) must be minimum 18” (45.7 cm)

above cooking surface.

o Wall cabinets directly above product must be minimum 36” (91.4 cm) for open top burners above

cooking surface.

Custom Gas Rangetops

Description

30” W. Models

36” W. Models

Overall width

29-7/8” (75.9 cm)

35-7/8” (91.1 cm)

Overall height
(from bottom)

To top of grate—9-1/4” (23.5 cm)

To top of island trim—9-1/8” (23.2 cm)

Additions to base
height

To top of backguard—add 8” (20.3 cm)

To top of high shelf—add 23-1/2” (59.7 cm)

Overall depth
(from rear)

To end of side panel—24-5/16” (61.8 cm)

To end of landing edge—28-1/16” (71.3 cm)

To end of knobs—28-9/16” (72.6 cm)

Cutout dimensions

Cutout width—30” (76.2 cm)

Cutout height—7-5/8” (19.4 cm)

Cutout depth—min. 24” (61.0 cm),

max. 25-3/4” (65.4 cm)

Cutout width—36” (91.4 cm)

Cutout height—7-5/8” (19.4 cm)

Cutout depth—min. 24” (61.0 cm),

max. 25-3/4” (65.4 cm)

Gas requirements

Shipped natural or LP/Propane gas; field convertible with conversion kit

(purchased separately); accepts standard residential 1/2” (1.3 cm) ID gas service line.

Gas manifold pressure

Natural 5.0” W.C.P. / Liquid propane L/P 10.0” W.C.P.

Electrical requirements

120 VAC/60 Hz 4ft. (121.9 cm), 3-wire cord with grounded 3-prong plug

Max. amp usage

0.5 amps

Surface burner rating
Natural/LP

18,500 BTU (5.4 kW)/16,600 BTU (4.9kW)

15,000 BTU (4.4 kW)/12,500 BTU (3.7 kW)

Griddle burner rating

NA

15,000 BTU Nat./12,500 BTU LP/Propane

(4.4 kW Nat/ 3.7 kW LP)

Char-Grill burner
rating

NA

18,000 BTU Nat./16,000 BTU LP/Propane

(5.3 kW Nat/ 4.7 kW LP)

Approximate
shipping weight

125 lbs.

(56.7 kg)

6B-150 lbs. (67.5 kg)

4G-160 lbs. (72.0 kg)
4Q-155 lbs. (69.8 kg)

All manuals and user guides at all-guides.com

Содержание VGRT5304BSS

Страница 1: ...king Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com F20637A EN 021510 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 2: ...t symbol This symbol alerts you to hazards that can kill or hurt you and others All safety messages will be preceded by the safety alert symbol and the word DANGER WARNING or CAUTION These words mean Hazards or unsafe practices which WILL result in severe personal injury or death DANGER Hazards or unsafe practices which COULD result in severe personal injury or death Hazards or unsafe practices wh...

Страница 3: ...ing and moving Possible use of appliance moving devices is recommended DANGER CHEMICAL HAZARD To avoid risk of property damage and or personal injury or death this appliance is not too be used as a heating source Benzene is a chemical which is part of the gas supply to this cooking product which is consumed in the flames during combustion Exposure to a small amount of benzene is possible if a gas ...

Страница 4: ...op of backguard add 8 20 3 cm To top of high shelf add 23 1 2 59 7 cm Overall depth from rear To end of side panel 24 5 16 61 8 cm To end of landing edge 28 1 16 71 3 cm To end of knobs 28 9 16 72 6 cm Cutout dimensions Cutout width 30 76 2 cm Cutout height 7 5 8 19 4 cm Cutout depth min 24 61 0 cm max 25 3 4 65 4 cm Cutout width 36 91 4 cm Cutout height 7 5 8 19 4 cm Cutout depth min 24 61 0 cm m...

Страница 5: ...1 2 59 7 cm Overall depth from rear To end of side panel 24 5 16 61 8 cm To end of landing ledge 28 1 16 71 3 cm To end of knobs 28 9 16 72 6 cm Cutout dimensions Cutout width 48 121 9 cm Cutout height 7 5 8 19 4 cm Cutout depth min 24 61 0 cm max 25 3 4 65 4 cm Gas requirements Shipped natural or LP Propane gas field convertible with conversion kit purchased separately accepts standard residentia...

Страница 6: ...may become hot and cause burns If a cabinet storage is to be provided the risk can be reduced by installing a rangehood that projects horizontally a minimum 5 12 7 cm beyond the bottom of cabinets Note Based on 24 61 cm deep cabinet Note Minimum clearance for back wall is 0 with backguard or high shelf Note If a rangetop hood is installed wall cabinets above the rangetop have a different minimum c...

Страница 7: ...ressure regulator on the incoming service line for safe and efficient operation since service pressure may fluctuate with local demand External regulators are not required on this rangetop since a regulator is built into each unit at the factory Under no condition bypass this built in regulator Manifold pressure should be checked with a manometer natural gas requires 5 0 W C P and LP gas requires ...

Страница 8: ...ng surface Be sure to remove the burner caps packaged in styrofoam below the burner grates Some stainless steel parts may have a plastic protective wrap which must be peeled off The interior should be washed thoroughly with hot soapy water to remove film residues and any dust or debris before being used then rinsed and wiped dry Solutions stronger than soap and water are rarely needed BURN HAZARD ...

Страница 9: ..._____________________________________________________________________________________ If service requires installation of parts use only authorized parts to insure protection under the warranty Keep this manual for future reference Service Registration Performance Checklist A qualified installer should carry out the following checks h Check top burner ignition See drawing for proper flame height o...

Страница 10: ..._____________________________________________________________________________ 18 Notes ________________________________________________________________________________________________________________________________________________________ ________________________________________________________________________________________________________________________________________________________ _______...

Отзывы: