manualshive.com logo in svg
background image

3

1. Remove the cover and screws.

2. Attach an appropriate U.L. approved cable connector in

the hole at the rear of the wiring box.

3. Remove roofing nails from shingles around the TOP and

SIDES of the cutout area only.Carefully lift the shingles
to allow the back flashing sheet on the blower housing to
fit under them.

4. Center the blower ring in the 11" diameter hole, making

sure that the 1¼" diameter electrical wiring hole aligns
with the hole in the wiring box.

5. Attach the blower to the roof with six (6) screws provided.

It is recommended that the screws be located inside the
blower housing. Drill pilot holes if necessary.

6. Using a good grade of roofing cement, seal all of the

shingles around the housing and flashing sheet as well
as the mounting screw heads.

7. Bring electrical wiring through the hole in the wiring box

and secure it according to local codes.

8. Make the electrical connections with the proper connec-

tor for the type of wiring being used. Connect black to
black, white to blue, and the green or bare wire to
grounding screw.

9. Replace cover and screws. Do not pinch wiring under the

cover.

10. Make sure damper opens and closes freely.

1. Place a large bead of caulk on the back side of the

housing all along the outer edges.

2. Center the blower ring in the 11" diameter hole, making

sure that the 1¼" diameter electrical wiring hole aligns
with the hole in the wiring box.

3. Attach blower to the wall with the six (6) screws pro-

vided. It is recommended that the screws be located
inside the blower housing. Drill pilot holes if necessary.

4. Using a good grade of caulk, seal all around the mount-

ing screw heads.

5. Bring electrical wiring through the hole in the wiring box

and secure it according to local codes.

INSTALL THE BLOWER

ROOF INSTALLATIONS

INSTALL THE BLOWER

WALL INSTALLATIONS

BLACK

TO

BLUE

120 VAC

LINE

IN

WHITE

TO

BROWN

GROUND

TO

GROUNDING

SCREW

BLACK

TO

BLUE

120 VAC

LINE

IN

WHITE

TO

BROWN

GROUND

TO

GROUNDING

SCREW

6. Make  the electrical connections with the proper con-

nector for the type of wire being used. Connect black to
black, white to blue, and green or bare wire to grounding
screw.

7. Replace cover and screws. Do not pinch wiring under

cover.

8. Make sure damper opens and closes freely.

9. Top and side flanges of the back plate may be covered

with trim strips. Do not block grille opening

at  bot-

tom with trim. It will adversely affect performance of the
blower.

BLACK

TO

BLACK

BLACK

TO

BLACK

WHITE

TO

BLUE

WHITE

TO

BLUE

Содержание VEV1500

Страница 1: ...ringdamageandnoisyand orunbalanced impellers keepdrywallspray constructiondust etc offpower unit 3 Please read specification label on product for further informa tion and requirements 4 Electrical circuit including speed control if used must be rated6AMPSminimum Blower Dimensions 25 x 30 828 x 12 724 PLAN THE INSTALLATION 1 Locate the blower so the length of the duct run and numberofelbowsneeded a...

Страница 2: ...ic 2 Mark and drill a guide hole centered between roof rafters 3 From the outside use the guide hole as a starting point to lay out the installation A Use a T square to measure 125 8 to the left of the guide hole then up 1211 16 to locate the top left corner of the layout B Starting from the top left corner mark the rectangu lar cutout 21 W x 20 H and remove only the shingles in this area C Mark a...

Страница 3: ...per opens and closes freely 1 Place a large bead of caulk on the back side of the housing all along the outer edges 2 Center the blower ring in the 11 diameter hole making sure that the 1 diameter electrical wiring hole aligns with the hole in the wiring box 3 Attach blower to the wall with the six 6 screws pro vided It is recommended that the screws be located inside the blower housing Drill pilo...

Страница 4: ...ate connectors VIKING RANGE CORPORATION GREENWOOD MISSISSIPPI 38930 USA 4 Wire black to black white to white and green or bare wire beneath green ground screw Replace wiring box cover 5 Attach rough in plate to the studs at the inside top of hood with 4 10 24 nuts provided 6 Connect ductwork to rough in plate and tape joint 7 Turn on power and check blower operation INSTALL THE ROUGH IN PLATE USE ...

Страница 5: ...er les pales ou de les rendre bruyantes débar rassez l appareil de la poussière de plâtre de construc tion etc 3 Veuillez lire l étiquette de spécifications du produit pour obtenir plus de renseignements notamment sur les nor mes 4 Le circuit électrique y compris la commande de régime le cas échéant doit avoir au minimum une puissance nomi nale de 6 ampères Dimensions de ventilateur 55 9 cm 22 x 7...

Страница 6: ...galité avec le faîte du toit il ne sera pas visible de la rue Rappelez vous la position approzimativeduventilateurlorsquevoustravaillerezà l intérieur du grenier 2 Marquez et percez un avant trou centré entre les chevrons du toit INSTALLATIONS SUR LE TOIT PRÉPARATION DE L INSTALLATION PRÉPARATION DE L INSTALLATION 3 Del extérieur utilisezl avant troucommepointdedépart pour tracer le plan d install...

Страница 7: ...1 po 3 2 cm de diamètre pour le câble électrique est aligné avec celui de la boîte de câblage 3 Fixez le ventilateur au mur avec les six 6 vis fournies Il est conseillé que les vis soient posées à l intérieur du boîtier Au besoin percez des avant trous 4 À l aide d un mastic de bonne qualité étanchez les têtes de vis d assemblage 5 Enfilez un câble électrique dans le trou de la boîte de câblage et...

Страница 8: ...38930 USA POSE DE LA PLAQUE DE RACCOR DEMENT UTILISATION ET ENTRETIEN Débranchez l alimentation électrique et verrouillez le pan neau d entrée d électricité avant de nettoyer ou de réparer l appareil NETTOYAGE Retirez le couvercle et passez soigneusement l aspirateur à l intérieur du boîtier Veillez à ne pas courber ou endom mager la roue du ventilateur LUBRIFICATION DU MOTEUR Le moteur est lubrif...

Отзывы: