READ AND SAVE THESE INSTRUCTIONS
MODEL VEV1500
EXTERIOR MOUNTED BLOWER
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOW-
ING:
1. Use this unit only in the manner intended by the manu-
facturer. If you have questions, contact the manufac-
turer or your distributor.
2. Before servicing or cleaning unit, switch power off at
service panel and lock the service disconnecting means
to prevent power from being switched on accidentally.
When the service disconnecting means cannot be
locked, securely fasten a prominent warning device,
such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
a qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction
codes and standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American So-
ciety for Heating, Refrigeration and Air Conditioning
CAUTION
1.
For general ventilating use only. Do not use to exhaust hazard-
ous or explosive material and vapors.
2.
To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3.
Please read specification label on product for further informa-
tion and requirements.
4.
Electrical circuit, including speed control, (if used), must be
rated 6 AMPS minimum.
Blower Dimensions
25 x 30.828 x 12.724
PLAN THE
INSTALLATION
1. Locate the blower so the
length of the duct run and
number of elbows needed
are kept to a minimum.
2. Where possible, blower
should be centered be-
tween wall studs or roof
rafters.
3. Avoid pipes, wires, or
other ductwork that may
be running through the
wall.
ALL INSTALLATIONS
MODEL
VOLTS
AMPS
CFM
DUCT SIZE
VEV1500
120
4.3
1500
10" DIA.
SPECIFICATIONS
INSTALLER: Leave This Manual With The Homeowner
HOMEOWNER: Use And Care Information On Page 4
MODEL VEV1500
EXTERIOR BLOWER
WALL HOOD
CANOPY
(island canopy
available)
10" ROUND
DUCT
SOFFIT
ROUGH-IN
PLATE
24" or 27"
18"
MODEL
VEV1500
EXTERIOR
BLOWER
WALL HOOD
CANOPY
(island canopy
available)
10" ROUND DUCT
SOFFIT
ROUGH-IN
PLATE
24" or 27"
18"
10" ROUND ELBOW
TYPICAL ROOF MOUNTED INSTALLATION
TYPICAL WALL MOUNTED INSTALLATION
Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall, or ceiling, do not
damage electrical wiring or other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce risk of fire, use only metal ductwork.
8. This unit must be grounded.
WARNING
FOR USE ONLY WITH VIKING VWH/VBCV/V
I
H/V
I
CV/DTWN - 42”W (ISLAND
ONLY) - 66”W. WALL AND ISLAND HOODS.