manualshive.com logo in svg
background image

Electrical & Gas Requirements

Electrical Requirements

There is no connection necessary beyond
plugging the unit into a polarized,
grounded, 120 volt, 60 Hz, 15 amp circuit. A
minimum of 120VAC is required for proper
operation of gas ignition systems.

DO NOT

use a GFI circuit. This circuit, however,

MUST

be grounded and properly polarized. The
unit is equipped with 16-3 SPT2 power cord.

Note:

If electrical power is not supplied or is

interrupted, the open top burners will have
to be lit manually with a match.

Gas Connection

The gas supply (service) line must be the
same size or greater than the inlet line of the
appliance. All cooktops use a 1/2” (1.3 cm)
I.D. NPT (Sch40) inlet. Sealant on all pipe
joints must be resistive to LP/Propane gas.

These cooktops are designed specifically for
natural gas. An (LP) gas conversion kit ships
standard with every unit. Before beginning
installation verify that the model is
compatible with the intended gas supply.

IMPORTANT: Any conversion required
must be performed by a qualified licensed
plumber or gas service company. The
proper conversion kit must be ordered
from your authorized service agency or
dealer.

Manual shut-off valve:

• The installer-supplied valve must be

installed in the gas service line ahead of
the appliance and regulator in the gas
stream and in a position where it can be
reached quickly in the event of an
emergency.

In Massachusetts:

A “T” handle type

manual gas valve must be installed in
gas supply line to the appliance.

Pressure regulator:

• All heavy-duty, commercial-type cooking

equipment must have a pressure regulator
on the incoming service line for safe and
efficient operation, since service pressure
may fluctuate with local demand. The
regulator supplied with the cooktops must
be installed before any gas connections
are made.

• Manifold pressure should be checked with

a manometer; natural gas requires 5.0”
WCP and LP/Propane requires 10.0” WCP.
Incoming line pressure upstream for the
regulator must be 1” WCP higher than the
manifold pressure in order to check the
regulator. The regulator used on this
cooktop can withstand a maximum input
pressure of 1/2 PSI (14.0” WCP).

If

the line pressure is in excess of that
amount, a stepdown regulator will be
required.

• The appliance must be disconnected from

the gas supply piping system during any
pressure testing of that system.

13

12

Rigid Connections:

• Incoming gas is brought from an intake

pipe (not supplied) at the rear of the unit
to the pressure regulator; then to the
manifold pipe for distribution. The only
connection necessary is from the service
supply, through the shut-off valve (not
supplied), to this intake pipe (not
supplied) to the regulator supplied, but
not connected through the cooktop.

In Massachusetts:

This appliance must be

installed with a 36” (3-foot) long flexible gas
connector.

LP/Propane Conversion

The RDGSU models are field convertible to
LP/Propane gas. The orifice spuds and
regulator must be physically changed. See
conversion kit and instructions included with
your cooktop. Gas conversions and initial
installation adjustments are not the
responsibility of the manufacturer.

Before placing the cooktop into operation,

always check for gas leaks with a soapy

water solution or other acceptable method.

DO NOT

USE AN OPEN FLAME TO

CHECK FOR LEAKS.

CAUTION

Electrical & Gas Requirements

Initial Ignition of Burners

All cooktops are tested before leaving the
factory. Field adjustments may be necessary
for proper mixture of gas and air for proper
operation. When the cooktop is connected
to gas and electrical service, it should be
adjusted by a qualified technician. If it is not,
contact your dealer for the name of their
authorized service agency in your area.

Proper Lighting and Shutdown
Instructions

1. To ignite the surface burners, turn the

knob counter clockwise to any position.

2. Upon ignition of the surface burner, turn

the knob to the desired position, (HI,
Med, or Low).

3. To shutdown the burner, turn knob

clockwise to the OFF position.

4. In case of failure, shut the gas OFF using

the installer supplied manual shut-off
valve.

All manuals and user guides at all-guides.com

Содержание D3

Страница 1: ...ion Viking Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Website at vikingrange com All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 2: ... unsafe practices which COULD result in severe personal injury or death Hazards or unsafe practices which COULD result in minor personal injury or property damage All safety messages will identify the hazard tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed WARNING CAUTION Table of Contents Warnings Important Safety Instructions _________...

Страница 3: ...Formaldehyde and soot are byproducts of incomplete combustion Properly adjusted burners with a bluish rather than yellow flame will minimize incomplete combustion WARNING ELECTRICAL GROUNDING INSTRUCTIONS The cooktop must be electrically grounded in accordance with local codes or in the absence of codes with the ANSI NFPA No 70 latest edition Installation should be made by a licensed electrician T...

Страница 4: ... gas outlet not including regulator Cutout depth 20 50 8 cm min to 20 1 4 51 4 cm max Gas requirements Ships standard for Natural Gas LP conversion kit included with unit Electrical requirements 115 V 50 60 Hz 4 ft 121 9 cm 3 wire cord with grounded 3 prong plug attached to product Maximum amp usage 1 0 amps Surface burner rating Left front Left rear Center Right front Right rear 9 100 Nat 9 000 L...

Страница 5: ...8 cm min to 20 1 4 51 4 cm max C 14 3 4 37 4 cm D 14 3 4 37 4 cm B C D A 20 5 8 52 3 cm 2 1 4 5 7 cm Downdraft Dimensions RDGSU200 RDGSU260 A 29 1 8 74 0 cm 34 7 8 88 6 cm B 27 68 6 cm 33 84 0 cm C 1 1 16 1 1 cm 15 16 1 0 cm D 1 1 16 2 7 cm 15 16 1 0 cm 30 W Cooktop RDGSU200 over 30 W Electric Oven RDSOE Note Refer to the oven installation instructions for undercounter dimensions Installation will...

Страница 6: ...approximately 6 15 2 cm below the countertop cutout and 12 30 5 cm from the right side of the cutout Minimum Clearances from Adjacent Combustible Construction Above countertop 36 91 4 cm minimum Side 8 20 3 cm Rear 2 1 2 6 4 cm min Within 6 side clearance Wall cabinets no deeper than 13 33 0 cm Must be minimum 18 45 7 cm above countertop Wall cabinets directly above the product must be minimum 36 ...

Страница 7: ...lator must be 1 WCP higher than the manifold pressure in order to check the regulator The regulator used on this cooktop can withstand a maximum input pressure of 1 2 PSI 14 0 WCP If the line pressure is in excess of that amount a stepdown regulator will be required The appliance must be disconnected from the gas supply piping system during any pressure testing of that system 13 12 Rigid Connectio...

Страница 8: ... hood Nothing should obstruct the flow of combustion and ventilation air Gas Manifold Pressure Natural gas 5 0 W C P LP Propane 10 0 W C P Flexible Connections If the unit is to be installed with flexible couplings and or quick disconnect fittings the installer must use a flexible connector of at least 1 2 I D 1 3 cm NPT with suitable strain reliefs and comply with ANSI Z21 41 and Z21 69 standards...

Страница 9: ...y installation dust or debris before being used for food preparation A qualified installer should carry out the following checks h Check top burner ignition The low flame should light at every port h Starting with the left front burner turn the corresponding knob to the HI position see drawing for proper flame height h Repeat steps for other burners 1 1 2 3 8 cm 3 8 0 95 cm Performance Checklist F...

Страница 10: ...ervice is ever required Model number ____________________________________________________________________________________ Serial number _____________________________________________________________________________________ Date of purchase __________________________________________________________________________________ Date installed _______________________________________________________________...

Отзывы: