manualshive.com logo in svg
background image

LP/Propane Tank Requirements

A dented or rusty LP/Propane tank may be
hazardous and should be checked by your tank
supplier. Never use a cylinder with a damaged
valve. All tanks should be equipped with an OPD
(overfilling protection device). This is a DOT
requirement for all tanks purchased after 
October 1, 1998 and will ensure that the tank is
not overfilled. The LP/Propane tank should be a
standard 5-gal, 20 lb. gas cylinder tank
approximately 12” in diameter and 18” high
which must be constructed and marked in
accordance with the Specifications for LP/Propane
Gas Cylinders of the U.S. Department of
Transportation (D.O.T.) or the National Standard
of Canada, CAN/CSA-B339, Cylinders, Spheres
and Tubes for Transportation of Dangerous
Goods; and Commission. The cylinder connection
device must be compatible with the Type 1,
QCC-1 connector on the outdoor cooking
appliance. 

All LP/Propane tanks must be mounted in a
vertical position for proper ventilation. The
cylinder must be provided with a shut-off valve
terminating in an LP/Propane gas supply cylinder
valve outlet specified. The cylinder supply system
must be arranged for vapor withdrawal and
provided with a listed overfilling prevention
device. If the appliance is stored indoors the
cylinder must be disconnected and removed from
the appliance. Each tank is supplied with a dust
cap. Place dust cap on cylinder valve outlet
whenever the cylinder is not in use. Only install
the type of dust cap on the cylinder valve outlet

that is provided with the cylinder valve.
Other types of caps or plugs may result in
leakage of propane. The cylinder used must
include a collar to protect the cylinder valve.
Cylinders must be stored outdoors in a well-
vented area out of the reach of children.

Built-In Installations

Built-in installations must be plumbed using a
fixed/hard line if the unit is going to be operated
at a distance exceeding 3 feet (0.91 meters) from
the fuel supply per ANSI Z21.24 CSA. Also, in a
built-in construction where an LP/Propane tank is
going to be used, there 

MUST

be some type of

support (braces, cutout, etc.) to prevent tank from
moving within the installation. The support must
also allow the LP/Propane tank to withstand a
horizontal tipping force equal to the weight of 
the tank without tipping over. The tank can not
tip over or deflect more than 1.00 inch when a 
8 lb. horizontal force is applied to a 20 lb.
LP/Propane tank

20

Содержание CVGBQ53024

Страница 1: ...Installation Guide 5 Series Outdoor Gas Grills ...

Страница 2: ...______________________________________________________6 Specifications 42 54 W Grill _____________________________________________________7 General Information__________________________________________________________________8 Clearance Dimensions ______________________________________________________________10 Cutout Dimensions _________________________________________________________________12 V...

Страница 3: ...all a ground fault interrupt CAUTION Conversions should only be performed by an authorized service technician WARNING ELECTRICAL SHOCK HAZARD This appliance is equipped with a 3 91 4 cm 3 prong power cord with a grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded receptacle Do not cut or remove the grounding prong from this plug This unit...

Страница 4: ... 29 73 6 cm 73 6 cm 29 7 8 29 7 8 75 9 cm 75 9 cm 17 1 4 17 1 4 43 8 cm 43 8 cm 10 1 2 10 1 2 26 7z cm 26 7z cm 30 W 36 W 35 7 8 35 7 8 91 1 cm 91 1 cm 29 29 73 6 cm 73 6 cm 34 3 8 34 3 8 87 3 cm 87 3 cm 17 1 4 17 1 4 43 8 cm 43 8 cm 10 1 2 10 1 2 26 7 cm 26 7 cm ...

Страница 5: ...Type 1 QCC 1 connection or standard residential 1 2 1 3 cm ID gas service line Electrical requirements 120VAC 60HZ 2 61 0 cm power cord supply cord with 3 prong grounded plug attached to grill 120VAC to 12VDC 2 61 0 cm power cord supply cord with 2 prong plug attached to rotisserie motor Grill burner rating 25 000 BTU Nat 22 500 BTU LP 7 3 kW Nat 6 5 kW LP Rotisserie burner rating 15 000 BTU Nat 1...

Страница 6: ...2 100 3 cm 100 3 cm 17 1 4 17 1 4 43 8 cm 43 8 cm 10 1 2 10 1 2 26 7 cm 26 7 cm 54 Grill Dimensions 42 54 W Grill 54 54 137 2 cm 137 2 cm 29 29 73 7 cm z 73 7 cm z 51 1 2 51 1 2 130 8 cm 130 8 cm 17 1 4 17 1 4 43 8z cm 43 8z cm 10 1 2 10 1 2 26 7 cm 26 7 cm 42 W ...

Страница 7: ...ne gas cylinder with Type 1 QCC 1 connection or standard residential 1 2 1 3 cm ID gas service line Electrical requirements 120VAC 60HZ 2 61 0 cm power cord supply cord with 3 prong grounded plug attached to grill 120VAC to 12VDC 2 61 0 cm power cord supply cord with 2 prong plug attached to rotisserie motor Grill burner rating 25 000 BTU Nat 22 500 BTU LP 7 3 kW Nat 6 5 kW LP TruSearTM burner rat...

Страница 8: ...n DOT or the National Standard of Canada CAN CSA B339 Cylinders Spheres and Tubes for the Transportation of Dangerous Goods Use only extension cords with a 3 prong grounding plug rated for the power of the equipment and approved for outdoor use with a W A marking Gas Manifold Pressure Natural gas 4 0 W C P LP Propane 10 0 W C P 8 WARNING This outdoor gas grill is not intended to be installed insid...

Страница 9: ...g surface However clearances from non combustible materials are not part of the ANSI Z21 58 scope and are not certified by CSA Clearances to non combustible materials must be approved by the authority having jurisdiction When determining a suitable location for the grill take into account concerns such as exposure to wind proximity to traffic paths and keeping gas supply lines as short as possible...

Страница 10: ...10 Clearance Dimensions 30 W 36 W Grill 30 W 36 W ...

Страница 11: ...11 Clearance Dimensions 42 54 W Grill 42 W 54 W ...

Страница 12: ...ways accessible accessible Electrical connection Electrical connection for power supply cord for power supply cord to be located on rear to be located on rear wall with a maximum wall with a maximum distance of 24 61 0 cm beneath distance of 24 61 0 cm beneath solid bottom support or a minimum solid bottom support or a minimum of 2 5 1 cm from floor of 2 5 1 cm from floor S o l i d b o t t o m S o...

Страница 13: ...lways accessible accessible Electrical connection Electrical connection for power supply cord for power supply cord to be located on rear to be located on rear wall with a maximum wall with a maximum distance of 24 61 0 cm beneath distance of 24 61 0 cm beneath solid bottom support or a minimum solid bottom support or a minimum of 2 5 1 cm from floor of 2 5 1 cm from floor S o l i d b o t t o m S ...

Страница 14: ...at the plug is always accessible Electrical connection for power supply cord to be located on rear wall with a maximum distance of 2 61 0 cm beneath solid bottom support S o l i d b o t t o m s u p p o r t Gas inlet and power cord location area 5 12 7 cm Countertop typically requires 1 2 5 cm wide by 1 2 5 cm deep notch cutout on each side of grill This allows grill CP to sit back properly in the ...

Страница 15: ...at the plug is always accessible Electrical connection for power supply cord to be located on rear wall with a maximum distance of 2 61 0 cm beneath solid bottom support S o l i d b o t t o m s u p p o r t Gas inlet and power cord location area 5 1 2 7 c m Countertop typically requires 1 2 5 cm wide by 1 2 5 cm deep notch cutout on each side of grill This allows grill CP to sit back properly in th...

Страница 16: ...or b For an enclosure having four sides a top and a bottom 1 At least two ventilation openings See Part IV Definitions shall be provided in the side walls of the enclosure located within 5 in 217 mm of the top of the enclosure equally sized spaced at a minimum of 90 degrees 1 57 rad and unobstructed The opening s shall have a total free area of not less than 1 in2 lb 1 42 cm2 kg of stored fuel cap...

Страница 17: ... off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 PSIG 3 5 kPa The gas grill must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of that system at test pressures equal to or less than 1 2 psi 3 5 kPa Built in installations must be ...

Страница 18: ...ow deep to bury the lines If the gas line is too small the grill will not function properly To connect the supplied regulator to the incoming flexible gas line attach with a female adaptor to a male flare adapter supplied by the installer to the gas line Ensure that the regulator arrow points in the direction of the gas flow towards the unit and away from the supply Attach the regulator assembly t...

Страница 19: ...nstalling gas supply lines Be sure to check on type and size of run and how deep to bury the lines If the gas line is too small the grill will not function properly To connect the supplied regulator assembly to the incoming flexible gas line attach with a 3 8 female flare adapter to the 3 8 male flare adapter to the regulator assembly Ensure that the regulator arrow points in the direction of the ...

Страница 20: ...ystem must be arranged for vapor withdrawal and provided with a listed overfilling prevention device If the appliance is stored indoors the cylinder must be disconnected and removed from the appliance Each tank is supplied with a dust cap Place dust cap on cylinder valve outlet whenever the cylinder is not in use Only install the type of dust cap on the cylinder valve outlet that is provided with ...

Страница 21: ...conducting Propane and Natural Gas CAN1 8 3 standard See LP Propane tank requirements below Each tank is supplied with a dust cap Place dust cap on cylinder valve outlet whenever the cylinder is not in use Only install the type of dust cap on the cylinder valve outlet that is provided with the cylinder valve Other types of caps or plugs may result in leakage of propane Attach the regulator assembl...

Страница 22: ...nnections on the grill are leak tested at the factory prior to shipment a complete gas tightness check must be performed at the installation due to possible mishandling in shipment or excessive pressure unknowingly being applied to the unit Periodically check the whole system for leaks or immediately check if the smell of gas is detected Do not smoke while leak testing Extinguish all flames Never ...

Страница 23: ...ylinder valve if it should become damaged The cylinder must be replaced If you are unable to stop a leak shut off the gas at the cylinder valve Remove the cylinder from the grill Call an authorized gas appliance service technician or LP Propane gas dealer Do not use the grill until the leak is corrected OFF 1 2 9 After checking for leaks push in and turn any control knob to release the pressure in...

Страница 24: ... to shipment however variations in the local gas supply may make it necessary to adjust the burners The flames of the burners except the rotisserie infrared burner should be visually checked and compared with the following illustrations Flames should be blue and stable with no yellow tips excessive noise or lifting If any of these conditions exist check if the air shutter or burner ports are block...

Страница 25: ...ter clockwise to allow more air to the burner If the flame is noisy and lifting away from the burner turn the air shutter clockwise to reduce the amount of air to the burner 7 Replace the drip tray When adjustments are complete turn the valve off tighten the air shutter screw and replace the landing ledge assembly ...

Страница 26: ... grill and resting the rounded end on the wheels on the left side of the grill WARNING ELECTRICAL SHOCK HAZARD This appliance is equipped with a grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded receptacle Do not cut or remove the grounding prong from this plug Motor Thumb Screw Mounting Bracket Skewer Rotisserie Fork 26 Once adjusted t...

Страница 27: ...to remove encrusted materials soak with hot wet cloths to loosen the material then use a wool or nylon scraper Do not use a metal knife spatula or any other material tool to scrape stainless steel Scratches are almost impossible to remove Service Registration Only authorized replacement parts may be used in performing service on the appliance All servicing should be referred to a qualified technic...

Страница 28: ... Range LLC 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit our website at vikingrange com in the US or brigade ca in Canada F21349B EN 031515 ...

Отзывы: