Clearance Dimensions

9

Note: 

Door handle of oven should be 36”

(91.4 cm) above the floor. 

Note: 

The grounded electrical socket should

be placed above or below cutout(s).

CAUTION

Burn hazard.

To avoid risk of personal injury;
the use of cabinets for storage
above the appliance may result

in a potential burn hazard. Combustible
items may ignite, metallic items may
become hot and cause burns.

CAUTION

To prevent possible damage to cabinets
and cabinet finishes, use only moisture
resistant materials and finishes that will
withstand temperature up to 190°F
(88°C). When cabinets are covered with
laminates, an appropriate heat-resistant
adhesive must be used. Consult your
manufacturer for proper specifications.

Electrical Requirements

Check your national and local codes

regarding this unit. These ovens require

3-wire, 120 VAC/60 Hz. 

See “Connecting

Gas & Electrical” section for grounding

instructions.

Gas Connection

The gas supply (service) line must be the

same size or greater than the inlet line of the

appliance. This oven uses a 1/2” (1.3 cm) ID

NPT (Sch40) inlet. Sealant on all pipe joints

must be resistive to LP gas.

These ovens are designed specifically for
natural gas or liquid propane (LP) gas. It is
shipped from the factory adjusted for use
with natural or propane (LP) gas. Before
beginning installation verify that the
model is compatible with the intended
gas supply.

Manual shut-off valve:

This installer-supplied valve must be installed

in the gas service line before the appliance

in the gas stream and in a location where it

can be reached quickly in the event of

an emergency.

In Massachusetts:

A “T” handle type

manual valve must be installed in the gas

supply line to the appliance.

IMPORTANT: Any conversion required
must be performed by your dealer or a
qualified licensed plumber or gas service
company

. Please provide the service person

with this manual before work begins.

WARNING

Electrical shock hazard.

To avoid the risk of electrical
shock, personal injury or death;
verify electrical power is turned

off at the breaker box and gas supply is
turned off until the oven is installed and
ready to operate, installation by an
authorized installer only.

Electrical & Gas Requirements 

Cutout Dimensions 

8

24”

(61.0 cm) min.

1-1/2”

(3.8 cm)

3”

(7.6 cm) dia.

14-1/4”

(36.2 c

m)

30-5/8”

(77.8 cm)

Electrical outlet to be located

in shaded area on rear wall

Gas inlet

location

3”

(7.6 cm)

28-5/8”

(72.7 cm)

21-5/16”

(54.1 cm)

17”

(43.2 cm) min.

30”

(76.2 cm)

Recommended

30”W. Cutout

All manuals and user guides at all-guides.com

Содержание Brigade CVGSO100

Страница 1: ...USA 662 455 1200 For product information call 1 888 845 4641 or visit our web site at www brigade ca F21108 EN 030113 BRIGADE TM Installation Guide Professional Built In Gas Thermal Convection Ovens...

Страница 2: ...product This may void the warranty All local and national codes and ordinances must be observed Installation must conform with local codes or in the absence of codes the National Fuel Gas Code ANSI Z2...

Страница 3: ...void risk of severe personal injury this appliance requires two or more personnel while handling and moving Possible use of appliance moving devices is recommended WARNING The use of cabinets for stor...

Страница 4: ...ble cord connector must be 1 2 ID 1 3 cm Cord must be agency approved for use with household gas ovens Maximum amp usage 1 2 amps Infrared broil burner rating 18 000 BTU Nat 5 3 kW Bake burner rating...

Страница 5: ...natural gas or liquid propane LP gas It is shipped from the factory adjusted for use with natural or propane LP gas Before beginning installation verify that the model is compatible with the intended...

Страница 6: ...ing or you observe unusual or excessive noise coming from the cooling fan contact an authorized service center before continuing operation Failure to do so can result in damage to the oven or surround...

Страница 7: ...e sealed Keep appliance area clear and free from combustible materials gasoline and other flammable vapors WARNING DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE SUCH USE MAY RESULT IN FIRE ELECTRIC...

Страница 8: ...ied licensed plumber or gas service company Connecting Gas Electrical DANGER Gas leak hazard To avoid risk of personal injury or death leak testing of the appliance must be conducted according to the...

Страница 9: ...DO NOT use a metal knife spatula or any other metal tool to scrape stainless steel Scratches are almost impossible to remove 2 The interior of the oven should be washed thoroughly with hot soapy water...

Страница 10: ...___________________________ These installation instructions should remain with the unit for future reference The model and serial number for your oven can be found by opening the door and looking on t...