manualshive.com logo in svg
background image

17

PERFORMANCE CHECKLIST

The installer should carry out the following performance checks.  Refer to instructions below.

1.  Check open top burner ignition.
2.  Check air shutter adjustment - sharp blue flame, no yellow tipping.  (See “Surface Burner Adjustment”)
3.  Check low flame adjustment - surface burner valve center stem adjustment.
4.  Check griddle ignition - all burner ports.
5.  Cycle griddle burner.
6.  Check air shutter adjustment - sharp blue flame, no yellow tipping.  (See “Grill/Griddle Burner Adjustment”)
7.  Check grill ignition - all burner ports.
8.  Check air shutter adjustment - sharp blue flame, no yellow tipping.  (See “Grill/Griddle Burner Adjustment”)
9.  Check low flame adjustment - grill valve center stem adjustment.

10  .  Visually check tubular burner reignition to be sure both sides are relighting each time.
11.  Check for gas leaks (odors) at all gas connections.
12.  Check oven bake  and convection bake function.  

NOTE:

This model is equipped with a direct spark ignition

system for both bake and broil burners.  On initial power up, there will be a 30-60 second delay for the electronics
to reset before ignition.

13.  Check self-clean function - door will lock and in approximately 30 seconds and the broil burner will ignite.  If there

is excess air in the gas line, the electrode will not sense flame and will shut-off gas to the burner.  Wait 30 seconds
and re-try ignition.  

CAUTION:  

Do not run self-clean cycle for more than 10 minutes with oven racks and rack

supports inside oven.  This could cause them to discolor due to the high temperature required for self-cleaning. 

FINAL PREPARATION

1.  Some stainless steel parts may have a plastic protective wrap which must be removed.  The interior of the oven

should be washed thoroughly with hot, soapy water to remove film residues and any installation dust or debris
before being used for food preparation, then rinsed and wiped dry.  Solutions stronger than soap and water are
rarely needed.

2.  All stainless steel body parts should be wiped with hot, soapy water and with a liquid cleaner designed for this

material.  If buildup occurs, do not use steel wool, abrasive cloths, cleaners, or powders!  If it is necessary to scrape
stainless steel to remove encrusted materials, soak with hot, wet cloths to loosen the material, then use a wood or
nylon scraper.  Do not use a metal knife, spatula, or any other metal tool to scrape stainless steel!  Scratches are
almost impossible to remove.

NOTE:  

These installation instructions should remain with the unit for future reference.  The electrical diagram is located

beneath the drip tray in the rear corner of the burner box.  Remove the right rear burner bowl and pull the drip tray
forward approximately 6” (15.2 cm).

INITIAL IGNITION OF BURNERS

All ovens are tested before leaving the factory.  When the oven is connected to the gas supply and the electrical
service, the installer should use the “Performance Checklist” for his final checks.  

NOTE:

This model is equipped with a

direct spark ignition system for both bake and boil burners.  On initial power up, there will be a 30-60 second delay for
the electronics to reset before ignition.

When adjustments are required, contact your dealer/installer for corrections.  If assistance is not available, contact
Viking Range Corporation Preferred Service for the nearest authorized service agent at (888) 845-4641.  All corrections
to installation are the responsibility of the dealer/installer or end user.

REPLACEMENT PARTS

Only authorized replacement parts may be used in performing service on the oven.  Replacement parts are available
from factory authorized parts distributors.  Contact Viking Range Corporation Preferred Service, (888) 845-4641, for the
nearest parts distributor in your area.

16

TIMING DIAGRAM:  NORMAL IGNITION CYCLE

TIMING DIAGRAM:  POWER UP CYCLE - IGNITION, FLAME LOSS

Flame Sense Current Measurement

Local Sense:

Connect a DC Micro-amp meter in series with the high voltage lead and the spark electode wire as shown.

Push switch to read current 

after

flame is established and the spark output is de-energized.

LOCAL SENSING:  CONNECT DC MICRO-AMP METER IN SERIES WITH HIGH VOLTAGE LEAD AS SHOWN

PUSH SWITCH TO READ CURRENT AFTER FLAME
IS ESTABLISHED AND SPARKING CEASES

Содержание 30" W. Models

Страница 1: ...poration 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For more product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com Viking Installation Guide Freestanding Gas Self Clean Ranges ...

Страница 2: ...n from the legs and internal mounting hardware It is strongly recommended that a pallete or lift jack be used rather than tilting NOTE If legs are removed from range and range rests on a combustible surface warranty and AGA CGA certification are void WARNING BACK TRIM ACCESSORIES Assembly and installation instructions are included with all back trim accessories IMPORTANT PLEASE READ AND FOLLOW Bef...

Страница 3: ... 1 1 4 3 2 cm To top of high shelf add 23 1 2 59 7 cm To top of 6 backguard add 6 15 2 cm Overall depth from rear To end of side panel 24 15 16 63 3 cm To end of control panel 27 7 8 70 8 cm To end of knobs 28 3 8 72 0 cm Electrical requirements 120 VAC 60 Hz 4 ft 121 9 cm 3 wire cord with grounded 3 prong plug attached to unit Gas requirements Shipped natural or LPL Propane gas field convertible ...

Страница 4: ...all appliances or other side vertical surfaces above 36 91 4 cm high There must be a minimum of 6 15 2 cm side clearance from the range to such combustible surfaces above the 36 91 4 cm counter height 3 Within the 6 15 2 cm side clearance to combustible vertical surfaces above 36 91 4 cm the maximum wall cabinet depth must be 13 33 0 cm and wall cabinets within this 6 15 2 cm side clearance must b...

Страница 5: ...ith gas fuel c In Massachusetts This appliance must be installed with a 36 3 foot long flexible gas connector CAUTION Leak testing of the appliance shall be conducted according to the manufacturer s instructions Before placing the oven into operation always check for leaks with a soapy water solution of other acceptable method DO NOT USE AN OPEN FLAME TO CHECK FOR LEAKS 8 IMPORTANT LEVELING ADJUST...

Страница 6: ...t holds the air shutter in place 3 Light the burner and turn the burner knob to the high position 4 With a proper high flame height adjust the air shutter to obtain a blue flame with no yellow tipping that sits on the burner at the burner ports a open the air shutter gap to add more air and to eliminate yellow tipping b close the air shutter gap to reduce the air and to prevent a noisy flame that ...

Страница 7: ...ctor 4 Grill Frame 5 Grill Burner Sheild Do not remove from burner 6 Burner Do not remove Illustration 3 Air shutter Air shutter adjustment screw Detail B Probe Bracket 12 SURFACE BURNER ADJUSTMENTS For Open Surface Burners See Illustration 2 To gain access to the surface burner adjustments 1 Remove the grates burner caps bowls and grate supports 2 Located the air shutter A and loosen the screw B ...

Страница 8: ...a valve and spark electrodes to provide a complete direct spark ignition system for gas ranges The DSI is a 0 2 DSI system 2 oven burner spark outputs with flame sense and valve enable safety supervision Contact closure inputs from the thermostat initiates micro controlled logic which supervises gas distribution to an oven burner and the ignition flame sense safety circuits Oven Burner Ignition Cl...

Страница 9: ...with a liquid cleaner designed for this material If buildup occurs do not use steel wool abrasive cloths cleaners or powders If it is necessary to scrape stainless steel to remove encrusted materials soak with hot wet cloths to loosen the material then use a wood or nylon scraper Do not use a metal knife spatula or any other metal tool to scrape stainless steel Scratches are almost impossible to r...

Страница 10: ...19 18 ...

Отзывы: