Description of Operation (con’t)

Lockout

The control will lockout if any self-checks fail during normal operation.  Also, the control will lockout if it failed to ignite
gas after the selected number of ignition attempts or ignition recycles.  In lockout the valve and ignition means are
turned off.  The control must be manually reset by cycling bake or broil off and back on.

Flame with Gas Valve Off

If there is proof of flame for ten seconds with the gas valve off, the control will go to lockout.  If there is flame for less
than ten seconds, the control will reset.

LOGIC FLOW DIAGRAM

14

DSI SPARK MODULE SPECIFICATIONS

Power Requirements

Input Voltage range (L1-N)

102 to 132 VAC, 60/50 Hz 135 mA current typical

Control Outputs

Bake or Broil Burner

Coil Pull-in pulse

54VDC +  10% @ 250mA

Coil Hold-in

36 mA minimum

Life Requirements

2000,000 cycles

Bake and Broil Spark:

16.5 KV @ 50 PFD load @ nominal conditions

Design Life

2,000,000 sparks

Spark Rate

3 sparks then 1 second delay (repeated Cadence)

Control Inputs

Flame Sense Type:

Flame Rectification

Minimum Flame Sense:

1

m

A. min.

Flame Sense Model:

A 25 M

W

resistor in series with a 1N4004 diode

Control Timing

All timings are 60 Hz; timings will be 20% longer at 50 Hz.  Times are +/- 0.2 seconds except for flame failure response
time.
Trial for ignition period

10.0 sec

Flame failure response time:

30.0 sec max.

Lock out time:

15.0 sec

Flame establishing period:

0.5 sec

Conditional prepurge time:

30.0 sec

Recycle time:

30.0 sec

Interpurge time:

30.0 sec

Ignition attempts:

3

Ignition recycles:

1

Description of Operation

Overview

The GDS/DSI control interfaces with a thermostat, a valve, and spark electrodes to provide a complete direct spark
ignition system for gas ranges.  The DSI is a 0 + 2 DSI system: 2 oven burner spark outputs with flame sense and valve
enable safety supervision.  Contact closure inputs from the thermostat initiates micro controlled logic, which supervises
gas distribution to an oven burner and the ignition/flame sense safety circuits.

Oven Burner Ignition

Closure of the thermostat output contacts (BR and/or BA) applies L1 to the Broil (J1-7) and/or Bake (J1-6) inputs.  The
Bake and/or Broil input is detected by the micro, which operates the gas valve and spark ignition sequence.  The Logic
Flow Diagram and Timing Diagram illustrates the typical valve/ignition supervision sequence provided by the micro as
follows:

Power up initializes the micro ports and performs an internal self-test and a flame safety check.  Failure of this
test sequence aborts operation in the lockout mode, which safety inhibits gas flow and sparking to prevent
ignition of any residual gas.

Verification of the safety checks initiates the Valve Trial Timer, which energizes the bake or broil solenoid.  The
spark output rate is coordinated to the flame sense sequence, confirmation of flame sense typically occurs after
2 sparks.  If flame is detected, the spark is inhibited, and the valve will be enabled/opened as long as flame
sense is normal and a call for heat is detected.  If flame is not detected, the spark rate will continue for the full
duration of Valve Trial Time.  Combustion failure during the ignition trial period or after the flame has been
established, will de-energize the solenoid for a 30-second interpurge time before initiating another trial for
ignition.  If the control fails to establish proof of flame after a specified number of ignition attempts, the
external lockout is executed.

Содержание 30" W. Models

Страница 1: ...poration 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For more product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com Viking Installation Guide Freestanding Gas Self Clean Ranges ...

Страница 2: ...n from the legs and internal mounting hardware It is strongly recommended that a pallete or lift jack be used rather than tilting NOTE If legs are removed from range and range rests on a combustible surface warranty and AGA CGA certification are void WARNING BACK TRIM ACCESSORIES Assembly and installation instructions are included with all back trim accessories IMPORTANT PLEASE READ AND FOLLOW Bef...

Страница 3: ... 1 1 4 3 2 cm To top of high shelf add 23 1 2 59 7 cm To top of 6 backguard add 6 15 2 cm Overall depth from rear To end of side panel 24 15 16 63 3 cm To end of control panel 27 7 8 70 8 cm To end of knobs 28 3 8 72 0 cm Electrical requirements 120 VAC 60 Hz 4 ft 121 9 cm 3 wire cord with grounded 3 prong plug attached to unit Gas requirements Shipped natural or LPL Propane gas field convertible ...

Страница 4: ...all appliances or other side vertical surfaces above 36 91 4 cm high There must be a minimum of 6 15 2 cm side clearance from the range to such combustible surfaces above the 36 91 4 cm counter height 3 Within the 6 15 2 cm side clearance to combustible vertical surfaces above 36 91 4 cm the maximum wall cabinet depth must be 13 33 0 cm and wall cabinets within this 6 15 2 cm side clearance must b...

Страница 5: ...ith gas fuel c In Massachusetts This appliance must be installed with a 36 3 foot long flexible gas connector CAUTION Leak testing of the appliance shall be conducted according to the manufacturer s instructions Before placing the oven into operation always check for leaks with a soapy water solution of other acceptable method DO NOT USE AN OPEN FLAME TO CHECK FOR LEAKS 8 IMPORTANT LEVELING ADJUST...

Страница 6: ...t holds the air shutter in place 3 Light the burner and turn the burner knob to the high position 4 With a proper high flame height adjust the air shutter to obtain a blue flame with no yellow tipping that sits on the burner at the burner ports a open the air shutter gap to add more air and to eliminate yellow tipping b close the air shutter gap to reduce the air and to prevent a noisy flame that ...

Страница 7: ...ctor 4 Grill Frame 5 Grill Burner Sheild Do not remove from burner 6 Burner Do not remove Illustration 3 Air shutter Air shutter adjustment screw Detail B Probe Bracket 12 SURFACE BURNER ADJUSTMENTS For Open Surface Burners See Illustration 2 To gain access to the surface burner adjustments 1 Remove the grates burner caps bowls and grate supports 2 Located the air shutter A and loosen the screw B ...

Страница 8: ...a valve and spark electrodes to provide a complete direct spark ignition system for gas ranges The DSI is a 0 2 DSI system 2 oven burner spark outputs with flame sense and valve enable safety supervision Contact closure inputs from the thermostat initiates micro controlled logic which supervises gas distribution to an oven burner and the ignition flame sense safety circuits Oven Burner Ignition Cl...

Страница 9: ...with a liquid cleaner designed for this material If buildup occurs do not use steel wool abrasive cloths cleaners or powders If it is necessary to scrape stainless steel to remove encrusted materials soak with hot wet cloths to loosen the material then use a wood or nylon scraper Do not use a metal knife spatula or any other metal tool to scrape stainless steel Scratches are almost impossible to r...

Страница 10: ...19 18 ...

Отзывы: