![Vigor V4324 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/vigor/v4324/v4324_operating-instructions-manual_1022907015.webp)
15
3 Design and Function
Overload protection: F250mA/600V fuse; F10A/600V fuse
3. Process and functional description
DC CURRENT
Range
Resolution
Accuracy
20
μ
A
0,01
μ
A
± 1 % of reading ± 2 digits
200
μ
A
0,1
μ
A
± 1 % of reading ± 2 digits
2 mA
1
μ
A
± 1 % of reading ± 2 digits
20 mA
10
μ
A
± 1 % of reading ± 2 digits
200 mA
100
μ
A
± 1,5 % of reading ± 2 digits
10 A
10 mA
± 3 % of reading ± 2 digits
Overload protection: 600V DC or rms. AC for all measuring ranges
Frequency range: 40Hz to 400Hz
Responding: average responding, calibrated in rms. of a sine wave
AC VOLTAGE
Range
Resolution
Accuracy
200 V
100 mV
± 1,2 % of reading ± 10 digits
600 V
1 V
± 1,2 % of reading ± 10 digits
Maximum open circuit voltage: 3.2V
Overload protection: 600V DC or rms. AC for all measuring ranges
RESISTANCE
Range
Resolution
Accuracy
200
Ω
0,1
Ω
± 0,8 % of reading ± 3 digits
2 k
Ω
1
Ω
± 0,8 % of reading ± 2 digits
20 k
Ω
10
Ω
± 0,8 % of reading ± 2 digits
200 k
Ω
100
Ω
± 0,8 % of reading ± 2 digits
2 M
Ω
1 k
Ω
± 1,0 % of reading ± 2 digits
Overload protection: 600V DC or rms. AC
DIODEN-DURCHGÄNGIGKEIT
Range
Description
If continuity exists (less than approx. 1.5k
Ω
), the built-in
buzzer will sound
Display of the approximate forward voltage drop of the diode