13

IM 04L75B01-01EN

DAQSTANDARD for DXAdvanced

Foreword

This section explains the special functions below 

of DAQSTANDARD for DXAdvanced, a dedicated 

PC software application for the DX3000 special 

specifications (log input and simulation function). For a 

description of other standard functions, see the DXA120 

DAQSTANDARD for DXAdvanced User’s Manual 

(IM04L41B01-61E).

 

Setup function for the log input and simulation 

functions

 

Setup file export function

Setup Function for the Log Input and Simulation 

Functions

■  Setup Function for the Log Input Function

The following setup items are added.

Setup Items That Are Added

Setup Page (Tab)

Log range setting

Measure channel

Setting of the number of displayed 

digits of the mantissa

Basic setting

Setup Function for the Log Input Function

•  “LOG” is added to the Delta/Scale/Sqrt area of the 

measure channel setup page (tab).

•  “LOG Scale” is added to the measure channel setup 

page (tab).

•  For details on the settings, see the “LOG Input 

Function” on page 7.

Setup Function for the Number of Displayed Mantissa 

Digits

•  The setting for the number of displayed mantissa digits 

is added to the Aux area of the Basic Setting page 

(tab).

•  For details on the settings, see the “LOG Input 

Function” on page 7.

■  Setup Function for the Simulation Function

The following setup items are added.

Setup Items That Are Added

Setup Page (Tab)

Time indicate ON/OFF setting

Basic setting

Settings for display freeze and 

memory clear

General setting

Setup Function for Turning ON/OFF the Time Display

•  The setting for turning ON/OFF the time indicate is 

added to the Aux area of the Basic Setting page (tab).

•  For details on the settings, see the “LOG Input 

Function” on page 7.

Setup Function for Display Freeze and Memory Clear

•  “Display Freeze/Active” and “Memory Clear” are added 

as actions when the event source is set to Remote 

in the Event Action area of the General Setting page 

(tab).

•  For details on the settings, see the “LOG Input 

Function” on page 7.

Setup File Export Function

•  The setup file can be exported (saved) to an Excel file 

or tab-separated text file.

•  From the 

File

 menu, point to Export and click 

Excel

 or 

Text

.

•  Specify the destination folder and file name and save 

the file.

 

Содержание Daqstation DX3004

Страница 1: ...DX3030 Daqstation DX3000 User s Manual Contents Introduction 1 Specifications Different from the DX2000 3 Checking the Package Contents 3 External Dimensions and Panel Cut Dimensions 5 Names of Parts...

Страница 2: ...gistration Thank you for purchasing YOKOGAWA products We invite you to register your products in order to receive the most up to date product information To register visit the following URL http www y...

Страница 3: ...4EN DXA120 Installing DAQSTANDARD IM 04L41B01 66EN Precaution on the use of the DX3000 IM 04L75B01 91EN Genaral Specifications Title General specifications No Paperless Recorder DX3000 GS 04L75B01 01E...

Страница 4: ...ES INCLUDING BUT NOT LIMITED TO PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES LOSS OF USE DATA OR PROFITS OR BUSINESS INTERRUPTION HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY WHETHER IN CONTRACT STRIC...

Страница 5: ...Dimension and Weight See External Dimensions and Panel Cut Dimensions Vibration 5 f 8 4 Hz amplitude 3 5 mm peak 8 4 f 160 Hz acceleration 9 8 m s2 The accompanying software application DAQSTANDARD fo...

Страница 6: ...RD IM 4L41B01 66EN 1 A4 size 4 CF card B8706NQ 1 128 MB The size and model may change Optional Accessories Sold separately The following optional accessories are available for purchase separately If y...

Страница 7: ...43 5 5 65 196 7 72 71 5 2 81 Ddimensions 480 4 min 18 91 195 3 2 0 7 69 435 9 2 0 17 16 227 1 min 8 94 7 5 0 3 10 5 0 41 Allowable panel thickness Unit mm approx inch Unless otherwise specified tolera...

Страница 8: ...ator Key panel Key panel Power switch Rear Panel USB port USB1 option Serial interface port C2 option A RS 232 interface connector Input terminals screw terminals Connect input signal wires from the m...

Страница 9: ...measure the DC voltage input DCV 20 mV 60 mV 200 mV 2 V 6 V 20 V and 50 V convert to logarithmic scale and display the data Selectable span range Same range as the DC voltage input Span Lower must be...

Страница 10: ...span value of the range to be 20000 The full span value of the range is the maximum value that can be set in the range It is 6 V in the 6 V range For example the A D normalized values in the 6 V range...

Страница 11: ...t voltage X Lower limit of display span VL Upper limit of display span VU Scale lower limit SL Scale upper limit SU Digital display value Y 1 Converting equation for the input voltage setting Y 10 SU...

Страница 12: ...ased in this condition the remote control input terminal will be open even though the memory is in a start condition Action Note Memory start stop Does not operate while the display is frozen Operates...

Страница 13: ...key Setup Screen Example for the Memory and Trend Clear Function Communication Commands The same command is used to control the display freeze function and memory and trend clear function QB p1 termin...

Страница 14: ...rent value mark setting is in AUX setting of the basic setting mode See Table 6 Fig 1 Current Value Mark Channel Type Channel Display of the Current Value Mark Three Digits Standard Two Digits Special...

Страница 15: ...p Function for the Number of Displayed Mantissa Digits The setting for the number of displayed mantissa digits is added to the Aux area of the Basic Setting page tab For details on the settings see th...

Страница 16: ...Blank...

Страница 17: ...Floor 129090 Moscow RUSSIA Phone 7 495 737 7868 Fax 7 495 737 7869 YOKOGAWA CHINA CO LTD 3F Tower D Cartelo Crocodile Building No 568 West Tianshan Road Shanghai 200335 CHINA Phone 86 21 62396262 Fax...

Отзывы: