Memory and Trend Clear Function

■  Specifications

•  A function used to clear the internal memory and the 

trend.

•  Clears the data area of the internal memory (data 

files that have been created are not cleared).

•  Can be executed while memory sample is in 

progress.

•  If you carry out the clear operation on the historical 

trend display, the display retains the condition before 

the operation.

•  If you execute memory and trend clear on a 

display other than the operation display, the screen 

automatically returns to the operation display.

•  Methods for clearing the internal memory and trend 

display

•  Event action function

•  Communication command

  For details, see the “

■ 

Communication Commands.”

■  Event Action Function

•  You can use the event action function to clear the 

internal memory and trend display.

  The “Clear the internal memory and trend display” 

action can be specified only when the event is set to 

“Remote.”

•  The “Clear the internal memory and trend display” 

action is executed only when an open-to-close event 

(rising edge) is detected.

■  Setting the Memory and Trend Clear Function

1.

  Press 

MENU

 (switch to the setting mode).

2.

  Select 

Timer

Event action

 > 

Event action

.

3.

  Set the 

Logic box number

Event

 (set to Remote), 

and 

Remote number

.

4.

  In the 

Action

 box, press the 

MemClear

 soft key.

            Setup Screen Example for the Memory and Trend 

Clear Function

 

Communication Commands

The same command is used to control the display freeze 

function and memory and trend clear function.
QB p1 <terminator>

  p1:  Switch the screen operation and clear the memory 

(0 to 2)

   0: Normal operation

   1: Freeze the display

   2: Clear the internal memory and trend display

Enabling/Disabling the Time Display

■  Specifications

•  A function used to disable the time display on the 

operation display.

•  Displays on which the time display is disabled

   See Table 4 Displays on Which the Time Display Is 

Enabled/Disabled and the Description.

Display Name

Description

Status display

Time display

Time

Trend display

Grid time display

Grid time

Message display

Written time

Circular display

Grid time display

Grid time

Message display

Written time

Historical trend 

display

Grid time display

Grid time

Message display

Written time

Alarm summary

Alarm time

Message summary Written time

Memory information Start time and stop 

time

Batch comment time

Cursor time display Cursor time

Summary display

Memory summary

Start/Stop time

Manual sample data 

time

Report data time

Message summary Alarm time

Alarm summary

Written time

Report data display Start time

Timeout time

Log display

Login log

Time

Error log

Time

Communication log Time

FTP log

Time

WEB log

Time

E-mail log

Time

SNTP log

Time

DHCP log

Time

MODBUS log

Time

Table 4 Displays on Which the Time Display Is Enabled/

Disabled and the Description

Содержание Daqstation DX3004

Страница 1: ...DX3030 Daqstation DX3000 User s Manual Contents Introduction 1 Specifications Different from the DX2000 3 Checking the Package Contents 3 External Dimensions and Panel Cut Dimensions 5 Names of Parts...

Страница 2: ...gistration Thank you for purchasing YOKOGAWA products We invite you to register your products in order to receive the most up to date product information To register visit the following URL http www y...

Страница 3: ...4EN DXA120 Installing DAQSTANDARD IM 04L41B01 66EN Precaution on the use of the DX3000 IM 04L75B01 91EN Genaral Specifications Title General specifications No Paperless Recorder DX3000 GS 04L75B01 01E...

Страница 4: ...ES INCLUDING BUT NOT LIMITED TO PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES LOSS OF USE DATA OR PROFITS OR BUSINESS INTERRUPTION HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY WHETHER IN CONTRACT STRIC...

Страница 5: ...Dimension and Weight See External Dimensions and Panel Cut Dimensions Vibration 5 f 8 4 Hz amplitude 3 5 mm peak 8 4 f 160 Hz acceleration 9 8 m s2 The accompanying software application DAQSTANDARD fo...

Страница 6: ...RD IM 4L41B01 66EN 1 A4 size 4 CF card B8706NQ 1 128 MB The size and model may change Optional Accessories Sold separately The following optional accessories are available for purchase separately If y...

Страница 7: ...43 5 5 65 196 7 72 71 5 2 81 Ddimensions 480 4 min 18 91 195 3 2 0 7 69 435 9 2 0 17 16 227 1 min 8 94 7 5 0 3 10 5 0 41 Allowable panel thickness Unit mm approx inch Unless otherwise specified tolera...

Страница 8: ...ator Key panel Key panel Power switch Rear Panel USB port USB1 option Serial interface port C2 option A RS 232 interface connector Input terminals screw terminals Connect input signal wires from the m...

Страница 9: ...measure the DC voltage input DCV 20 mV 60 mV 200 mV 2 V 6 V 20 V and 50 V convert to logarithmic scale and display the data Selectable span range Same range as the DC voltage input Span Lower must be...

Страница 10: ...span value of the range to be 20000 The full span value of the range is the maximum value that can be set in the range It is 6 V in the 6 V range For example the A D normalized values in the 6 V range...

Страница 11: ...t voltage X Lower limit of display span VL Upper limit of display span VU Scale lower limit SL Scale upper limit SU Digital display value Y 1 Converting equation for the input voltage setting Y 10 SU...

Страница 12: ...ased in this condition the remote control input terminal will be open even though the memory is in a start condition Action Note Memory start stop Does not operate while the display is frozen Operates...

Страница 13: ...key Setup Screen Example for the Memory and Trend Clear Function Communication Commands The same command is used to control the display freeze function and memory and trend clear function QB p1 termin...

Страница 14: ...rent value mark setting is in AUX setting of the basic setting mode See Table 6 Fig 1 Current Value Mark Channel Type Channel Display of the Current Value Mark Three Digits Standard Two Digits Special...

Страница 15: ...p Function for the Number of Displayed Mantissa Digits The setting for the number of displayed mantissa digits is added to the Aux area of the Basic Setting page tab For details on the settings see th...

Страница 16: ...Blank...

Страница 17: ...Floor 129090 Moscow RUSSIA Phone 7 495 737 7868 Fax 7 495 737 7869 YOKOGAWA CHINA CO LTD 3F Tower D Cartelo Crocodile Building No 568 West Tianshan Road Shanghai 200335 CHINA Phone 86 21 62396262 Fax...

Отзывы: