background image

5

Installation Instructions

Visit the ViewZ USA website at http://www.viewzusa.com

+V

 ADJ.

LED

1

2

3

4

5

6

7

8

9

VZ-DC24-320 Power Supply

*Use 18AWG Copper Wire or larger for output power

Wiring

1. 

Connect wires from monitor to the terminal blocks (V+) and (V-) using a Phillips screwdriver. 

To avoid damaging the monitor, use correct polarity.

2. 

Once unit is powered, the amount of output voltage can be adjusted (+V ADJ), if needed for 

longer cable runs that have resulted in a voltage drop.

Voltage Adjustment ~24V DC to 27V DC 

Clockwise to increase Voltage

Voltage Output (Positive, +)

Voltage Output (Negative, -)

Ground

Line In (Neutral)

Line In (Load)

L

N

-V

+V

+V ADJ.

+V ADJ.

Diagram of Power Supply Connections

Содержание VZ-DC24-320

Страница 1: ...ViewZ DC 24 30 Power Supply VZ DC24 320 Field Wiring and Mounting Instructions VZ DC24 320 ...

Страница 2: ...2 Installation Instructions Visit the ViewZ USA website at http www viewzusa com VZ DC24 320 Power Supply Installation Tools 3 Warning Statements 3 Mounting 4 Wiring Warranty 5 6 Contents ...

Страница 3: ...sing NEC ANSI NFPA 70 Article 310 Do not install near water high moisture open flames or sources of high levels of heat The wire s rated Ampacity for output cabling must be derated by multiplying by 0 8 as specified in ANSI NFPA Article 645 5A Power output cabling must be housed within a cable tray conduit or plenum area for continuous protection to the cabling Always crimp a UL listed ring termin...

Страница 4: ...ted 2 Drill in mounting screws away from wall Pilot holes might be needed 3 If not drilling to a stud use proper fastener support e g drywall anchor 4 Place the Power Supply Box Keyholes over the mounting screws 5 Secure the Power Supply by tightening screws If mounting to wall studs or ceiling studs make sure that the mounting screws are anchored into the center of the wall studs or ceiling studs...

Страница 5: ...cks V and V using a Phillips screwdriver To avoid damaging the monitor use correct polarity 2 Once unit is powered the amount of output voltage can be adjusted V ADJ if needed for longer cable runs that have resulted in a voltage drop Voltage Adjustment 24V DC to 27V DC Clockwise to increase Voltage Voltage Output Positive Voltage Output Negative Ground Line In Neutral Line In Load L N V V V ADJ V...

Страница 6: ...tomers Must Do for Limited Warranty Service If you discover a problem that you think may be covered by the warranty you MUST REPORT it in writing to the address below within thirty 30 days Proof of purchase an original sales receipt from the original consumer purchaser must accompany all warranty claims Warranty claims must also include a description of the problem the purchaser s name address and...

Отзывы: