Instrument alignment
1. Preparation of manual alignment
2. Color temperature alignment
3. Factory preset setting
4. Download serial number procedure
1. Preparation of manual alignment
1.1 The alignment procedure is performed after unit been completely assembled and before set
inspection.
1.2 Before set been aligned, set should be burn
ed
-
in for over 30min.
1.3
Measuring equipment used
Pre-programmed chroma 2226 or equivalent.
Color
i
meter
M
ino
l
ta CA110 or equivalent.
1.4 Method to enter/exit factory mode
1.4.1 Press “VOL+” and “1” and “Down” Key simultaneously 3 times when
display is powered
on
with a
n
image.
1.4.2 To ensure the monitor is under factory mode, check following OSD image display
.
Otherwise, follow the procedure. Described in session 1.4.1 to enter the factory mode again.
1.4.3 Under factory mode, press “ 1” Key. The monitor will exit factory mode and under ordinary
C A 1 1 0
2 1 0
m m
Firmware Version
Factory Mode
Factory Default
Color Temp. Manual
1: Exit
2: Select
ViewSonic Corporation
Confidential
– Do Not Co
py
VX500+-1
4
6
8
.
ADJUSTING PROCEDURE
Содержание VX500PLUS-1
Страница 42: ...FIG 13 AUDIO SINE SIGNAL OUT ViewSonic Corporation Confidential Do Not Copy VX500 1 39...
Страница 54: ...A A A A ViewSonic Corporation Confidential Do Not Copy VX500 1 51 10 EXPLODED PARTS VIEW...
Страница 55: ...ViewSonic Corporation Confidential Do Not Copy VX500 1 52...
Страница 56: ...ViewSonic Corporation Confidential Do Not Copy VX500 1 53...
Страница 57: ...ViewSonic Corporation Confidential Do Not Copy VX500 1 54...
Страница 60: ...ViewSonic Corporation Confidential Do Not Copy VX500 1 57 11 BLOCK DIAGRAM...
Страница 67: ...ViewSonic Corporation Confidential Do Not Copy VX500 1 64 13 PCB LAYOUT DIAGRAM...
Страница 68: ...ViewSonic Corporation Confidential Do Not Copy VX500 1 65...