45
Other Information
ENGLISH
ViewSonic
VT3205LED
§ Table 5-1 outlines the Get-function command list that must be supported by the LCD
Monitor.
Table 5-1: PC Get-function command to LCD Monitor
Get Function
Command
Code
(ASCII)
Command
Code
(Hex)
Response Range
(Three ASCII bytes)
Comments
Get-Contrast
a
61
000 ~ 100
Gets Contrast value
Get-Brightness
b
62
000 ~ 100
Gets Brightness value
Get-Sharpness
c
63
000 ~ 100
Gets Sharpness value
Get-Color
d
64
000 ~ 100
Gets Color value
Get-Tint
e
65
-50 ~ +50
Gets Tint value
Get-Volume
f
66
000 ~ 100
Gets Volume value
Get-Mute
g
67
000: OFF (unmuted)
001: ON (muted)
Gets Mute ON/OFF status
Get-Input select
j
6A
000: TV
001: AV
002: SV
003: YPBPR
004: HDMI 1
005: HDMI 2
006: VGA
Gets Input select status
Get-Power status
l
6C
000: STBY
001: ON
Gets the status of the HDTV power.
HDTV response:
000 = HDTV is in standby
001 = HDTV is ON
Get-Remote
Control
n
6E
000: DISABLE
001: ENABLE
002: PASS
THROUGH
Disable:
RCU has no effect on HDTV.
Enabled:
RCU controls the HDTV. This
is the power up default on the HDTV.
Pass through:
RCU has no effect on
HDTV and all RCU command codes are
transmitted to FC via the RS232 port. See
page 51 for more details
Get-Power Lock
o
6F
000: Unlock
001: Lock
Get-Button Lock
p
70
000: Unlock
001: Lock
Get-Menu Lock
q
71
000: Unlock
001: Lock
Get-ACK
z
7A
000
This command is used to test the
communication link.