background image

3

5472 726 - 02

Vitotron 100 Electric Space Heating Hot Water Heater Installation/Service

Instructions for the Installer

 

Safety Instructions

8.   This space heating hot water heater is equipped 

 

with a 194°F manual reset safety high limit device. 

 

The reset button is clearly located in the center of 

 this 

device.

9.   This space heating hot water heater will not operate  

 

below a 7 psi water pressure level.

10. This space heating hot water heater is equipped  

 

with a Wilo circulator pump. After thermostat    

 

temperature set point has been reached the pump 

 

will continue to circulate water for 3 additional  

 

minutes as part of a post purge sequence to push  

 

heated water away from heat exchanger.

11. This space heating hot water heater is equipped  

 

with a differential pressure relief bypass valve. 

 

It allows the system to keep minimal flow of    

 

heating water through the space heating hot water  

 

heater and reduce noise in the installation when  

 

equipped with thermostatic zone valves.

12. Do not drain the water from the space heating hot  

 

water heater after the heating season.

13. In summer do not shut off the power supply (120VAC  

 

and 240VAC) and leave the controller in stand-by  

 

(summer mode) between the heating seasons.   

 

The space heating hot water heater is equipped with  

 

an exercise timer control feature that allows the  

 

circulating pump to operate 15 minutes each day and  

 

will ensure longer operation the circulating pump and  

 

will help to eliminate the buildup of debris. (See  

 

section “Summer mode (stand-by mode)”on page 11).

14. Space heating hot water heater is pre-set by the  

 

manufacturer to work with hydronic radiant floor,  

 

radiant ceiling, hot water baseboard and water to air  

 

heat applications. Temperature adjustments can be  

 

made on control panel to meet these applications  

 

requiring desired water temperatures between 85° -  

 140°F.

1.   Read and strictly follow the installation and operating  

 

instructions to ensure a longevity and reliable space  

 

heating hot water heater operation.

2.   This manual provides general installation guidelines.  

 

Your installation must comply with ALL applicable  

 local 

codes.

3.  

 Always have a qualified electrician perform   

 

electrical wiring. Manufacturer will not be held   

 

responsible for faulty installations which are performed

  

by unqualified electricians. An efficient electrical  

 

installation which has been completed in accordance  

 

with the binding norms of electric installation. 

 

Electric installation should be equipped with electric  

 

circuit breakers and other solutions which will ensure  

 

disconnecting the space heating hot water heater  

 

from the source of power.

4.   All installation work must be performed when the  

 

power and water supply is disconnected from the  

 

main electrical panel.

5.   This space heating hot water heater must be installed  

 

vertically and on an even wall surface with access to  

 

plumbing connections on bottom.

6.   Any associated components (i.e. space heating hot  

 

water heater, water tubing, valves, manifolds etc...)  

 

must be flushed before space heating hot water  

 heater 

installation.

7.   This space heating hot water heater is equipped with  

 

a safety relief valve. Do not install any barrier fitting  

 

or valve on the outlet of the safety valve. Connect  

 and 

extend 

c

 in. copper piping from relief valve and  

 

terminate at least 6 in. from the floor or floor drain.

Содержание Vitotron 100

Страница 1: ...eating contractor Please file in Service Binder Read and save these instructions for future reference Product may not be exactly as shown IMPORTANT Vitotron 100 VLN2 Models 04 to 14 4 Wall mounted ele...

Страница 2: ...ace Heating Hot Water Heater View 19 Parts List 20 Space Heating Hot Water Heater Parts 21 Instructions for the Installer Instructions for the User Page Table of Contents This appliance is not intende...

Страница 3: ...ter is pre set by the manufacturer to work with hydronic radiant floor radiant ceiling hot water baseboard and water to air heat applications Temperature adjustments can be made on control panel to me...

Страница 4: ...0 33 3 50 0 60 0 Breaker Quantity Amps A 1 30 amp 1 40 amp 1 50 amp 1 60 70 amp 1 80 amp Heating Elements Quantity 3 Element Resistance each 43 3 28 8 21 6 14 4 12 0 Circulating Pump Wilo Star S 21 U...

Страница 5: ...or the Installer Space Heating Hot Water Heater Mounting Clearances After reading instructions please keep this manual with the space heating hot water heater for future reference Affix the plastic ho...

Страница 6: ...Space heating hot water heater 2 Additional expansion tank if needed Space heating hot water heater piped in a primary secondary P S configuration Consider P S when higher flow rates are necessary an...

Страница 7: ...e than a 50 50 ratio of water to propylene glycol be used Consult with radiant system designers for required freeze protection guidelines Designed Temperature Differential Radiant floor heating system...

Страница 8: ...ccess to the valve is only from the bottom of the space heating water heater From there it can be connected any pressure gauge to check the pressure or pump to refill the air inside the tank 5 The spa...

Страница 9: ...of 7 psi in order to operate Pressure levels for hydronic systems typically are above the pre charged expansion tank pressure level 12 psi If additional pressure gauges are installed verify reading a...

Страница 10: ...grounded in accordance with National Electrical Code ASNI NFPA70 or local codes 3 This space heating water heater operates with 240VAC single phase electrical power source 4 Connect the space heating...

Страница 11: ...ize b electrical knockout to left side of control panel to gain entrance to this connection Install thermostat in a location where it will not be influenced by other heat sources 7 Off peak control op...

Страница 12: ...perature Fahrenheit Buttons Space heating water heater power Up and down selection Scroll option Failures indication Indicator Status Details EEE Message on electronic display Data record error Parame...

Страница 13: ...he current working mode of the space heating water heater 2 Set the supply water temperature SWT set point Utilize the right arrow push button to scroll through working parameters of the space heating...

Страница 14: ...when the outdoor sensor is wired to Text terminals on control panel Manual setting see parameter 4 in advanced settings outlet temperature can be set manually in range 85 140 F Use buttons and to chan...

Страница 15: ...For example 30 F outdoor temperature and the desired 110 F for hydronic system can lead to a selection of curve 3 or 4 It should be checked periodically whether the choice was correct if not another c...

Страница 16: ...me when the space heating water heater is switched to summer mode For example if you turn the space heating water heater to stand by mode at 6 p m the timer will activate the pump every day for 15 min...

Страница 17: ...ount kW as indicated on identification label This value is factory preset 2 A n Working mode of pump PA automatic Pn manual continuous duty of pump 3 1 2 3 Maximum quantity of active heating elements...

Страница 18: ...eat and is above ambient temperature set point Verify connections on thermostat Failure of control board Check fuse on control panel glass fuse 6 3 x 32 mm 2A Heating status blinks Off Peak signal no...

Страница 19: ...19 5472 726 02Vitotron 100 Electric Space Heating Hot Water Heater Installation Service General Space Heating Water Heater View Instructions for the User...

Страница 20: ...vice Part List Instructions for the User Legend 1 Wiring Entrance 2 Control Panel 3 Pump 4 Pressure Relief Valve 5 Pressure Sensor 6 Magnetic Filter 7 Manual Reset High Limit Device 8 Heating Element...

Страница 21: ...NG BOX 14 4KW 240V VLN2 7873778 RETURN CONNECTION PIPE VLN2 7873779 PUMP CONNECTION PIPE INTERNAL VLN2 7873780 POWER BOARD WITHOUT CONNECTION VLN2 7873781 POWER BOARD W CONNECTION VLN2 7873782 FLOW CO...

Страница 22: ...22 5472 726 02 Vitotron 100 Electric Space Heating Hot Water Heater Installation Service...

Страница 23: ...23 5472 726 02Vitotron 100 Electric Space Heating Hot Water Heater Installation Service...

Страница 24: ...0 Electric Space Heating Hot Water Heater Installation Service Technical information subject to change without notice Printed on environmentally friendly recycled and recyclable paper Scan for digital...

Отзывы: