Boiler Connections
29
Installation Examples
(continued)
System layout 1
Vitodens 200-W, WB2B with a direct-connected heating circuit
Legend
AV
Air vent (models WB2B 19, 26, 35)
PRV
Pressure relief valve
TPV
Temperature and pressure relief valve
Vitodens 200-W WB2B boiler with
Vitotronic 200, HO1 outdoor reset
control
Outdoor temperature sensor
Remote control Vitotrol 300 (optional)
Heating circuit
Heating circuit pump
sÖ
*
DHW circulating pump
sA
*
DHW storage tank
DHW tank temperature sensor
I
Expansion tank
J
Flow check valve
DHW recirculation pump
sK
*
Power/Pump module
M
Optional purge tee (field supplied)
*
See pages 52 and 56.
Installation of ...
H
radiator heating circuit (high-temp. circuit)
H
DHW production
... with the following flow conditions:
The flow rate of the heating circuit is
less
than the maximum possible water flow rate
of the Vitodens 200-W WB2B boiler (see
page 28 for maximum water flow rate of
boiler).
The use of a low-loss header is strongly
recommended if the maximum water flow
rate in the application concerned exceeds
the values shown in the applicable table on
page 28, or if the system flow rates are
unknown.
The low-loss header is available as
accessory part.
See following pages for installation
examples with a low-loss header.
DHW circulating pump
must pump
into
the Vitodens 200-W boiler (as illustrated).
5
3
6
9
2
9
7
v
1
.6
5
1
PRV
TPV
A
B
C
K
AV
M
D
E
F
G
H
L
J
I
Fig. 23