Technical water inertial storage tanks

 

12

 

 

6020938-02 

7

 

INSTALLATION 

 

CAUTION: All the operation described below must be done by QUALIFIED PERSONNEL ONLY. 

Before any operation on the unit, make sure that the electric power supply of all the devices on 

which they must operate is disconnected.

 

7.1

 

GENERAL

 

When installing the unit, it is necessary to strictly follow the rules listed in this manual, to observe all the 

indications and however to take all possible precautions. Failure to comply with the rules reported on this 

manual can create dangerous situations. 

 

After receiving the unit, immediately check its integrity. The unit left the factory in perfect 

condition; any damage must be immediately reported to the carrier and recorded on the Delivery 

Note before signing it. 

The company must be informed, within 8 days, of the extent of the damage. The Customer should prepare a 

written statement of any severe damage. 

 

CAUTION: The units are designed for outdoor installation. The installation place must be without 

any fire risks. Therefore all the necessary measures should be adopted in order to prevent the risk 

of fire at the installation place. The outside temperature must never exceed 46°C. Beyond this 

value, the unit is no longer covered by the current regulations in the field of safety of pressure 

equipment. 

 

CAUTION: The unit must be installed so as to allow free movement for repair and maintenance 

operations. The warranty does not cover costs for platforms or other lifting equipment needed for 

any interventions. 

 

All the maintenance operations and tests must be done by QUALIFIED PERSONNEL ONLY.

 

 

After the maintenance operations, close the panels by fixing them with screws.

 

7.2

 

LIFTING AND HANDLING

 

During unloading and positioning of the unit, utmost care 

must be taken to avoid abrupt or violent manoeuvres in 

order to protect the internal electronic components. The 

units can be lifted by means of a forklift or, in alternative, 

with belts, being sure not to damage the side panels and 

the cover. It is important to keep the unit horizontal 

during these operations. 

 

7.3

 

POSITIONING AND MINIMUM TECHNICAL CLEARANCES

 

All the models of the ACT series are designed and built for outdoor installation; for installation, you should 

follow the recommended placement and minimum technical clearances given in the table. It is advisable to 

create a suitably sized supporting base for the unit. 

Содержание Vitocal 100-A Series

Страница 1: ...6020938 02 7 2020...

Страница 2: ...T 6 7 INSTALLATION 12 7 1 GENERAL 12 7 2 LIFTING AND HANDLING 12 7 3 POSITIONING AND MINIMUM TECHNICAL CLEARANCES 12 7 4 INSTALLATION 13 7 5 PLUMBING CONNECTIONS 14 7 5 1 Plumbing connections between...

Страница 3: ...eference material We also decline any responsibility for possible inaccuracies in the manual if due to printing or transcription errors The customer shall store any updated copy of the manual or parts...

Страница 4: ...he inertial tank is discharged and disconnected from the plant Maintenance personnel must receive suitable training for the performance of their tasks in safety Operators must know how to use personal...

Страница 5: ...be easily installed inside the structure without the need for additional spaces and connections to add an electric heater for technical water heating In addition each model is supplied with a charge d...

Страница 6: ...ield which identify the ACT series in any customisations the MC field consists of two digits 011960 VS RE KI 00 MC MAIN CODE SIZE FACTORY FITTED ACCESSORIES 011960 VS RE KI Tank volume Electric heater...

Страница 7: ...ic kit consisting of an electric heater a probe thermowell and 2 electric panels containing terminals thermostats and a sensing bulb to insert into the thermowell of the probe All components should be...

Страница 8: ...e beginning any type of operation make sure that power is disconnected Connect the conductors in order phase neutral and earth The supply voltage s fluctuations cannot exceed 10 of the nominal value I...

Страница 9: ...ACT Technical water inertial storage tanks 8 6020938 02 endanger the proper operation of the unit...

Страница 10: ...fied by Approvato Approved by Titol o Title Schema elettrico ACT 1ph R 2 3 4 5 kW Codice Code Oggetto Object Schema elettrico Electrical drawing Foglio S heet 1 di of 1 Tuttele informazioni contenuten...

Страница 11: ...19 00 First emiss ion 05 06 2017 A B A B A B Rev Item Descrizione modifiche Description of changes Data Date Disegnato Drowing by Verificato Verified by Approvato Approved by Titol o Title Schema elet...

Страница 12: ...ev Item Descrizione modifiche Description of changes Data Date Disegnato Drowing by Verificato Verified by Approvato Approved by Titolo Title Schema elettrico ACT R 1 2 kW Codice Code Ogg ett o Objec...

Страница 13: ...prevent the risk of fire at the installation place The outside temperature must never exceed 46 C Beyond this value the unit is no longer covered by the current regulations in the field of safety of...

Страница 14: ...e omega support using the fixing screws and washers supplied in the threaded inserts already prepared Place between the Vitocal 100 A unit and the anti vibration dampers supplied and before the start...

Страница 15: ...ater circuit All pipes must be insulated with closed cell material of adequate thickness The water circuit should include the following components Well thermometers to monitor the circuit s temperatur...

Страница 16: ...etely discharged use the provided service valve It is advisable to install a suitable discharge pipe in order to preserve the surrounding area and to drain the technical fluid following standards in f...

Страница 17: ...te gaskets Check that all panels are positioned correctly and well fixed with screws CAUTION IT IS REQUIRED TO REDUCE THE PRESSURE OF THE EXPANSION VESSEL OF THE Vitocal 100 A UNIT TO 1 5 BAR 9 SHUTDO...

Страница 18: ...rained personnel and sent to proper collection centres the compressors lubricating oil has to be collected and sent to proper collection centres the electronic components such as regulators driver boa...

Страница 19: ...xpansion Vessel Kit for all sizes Capacity litres 18 Operating pressure bar 1 3 Max pressure bar 3 0 Operating weight kg 15 TECHNICAL SPECIFICATIONS Unit of Electrical Heater Kit for all sizes Power k...

Страница 20: ...ociated unit s code which you can read on the technical label applied on the unit itself Heater Model Maximum input power Maximum input current Fuses Power supply 2 kW SINGLE PHASE 2 kW 8 70 A 10 A 23...

Страница 21: ...rint with Vitocal 100 A ranges VARIATION OF THE HEIGHT A DEPENDING ON THE ADJUSTMENT OF SUPPORTING FEET MODEL Vitocal 100 A MINIMUM MAXIMUM AWO M AC 101 A06 AWO M AC 101 A08 1270 mm 1293 mm AWO M AC 1...

Страница 22: ...igurations there is a handbook which is a technical notebook including a series of system diagrams that have been highlighted regarding the installation configuration of our high efficiency heat pumps...

Страница 23: ...r inertial storage tanks 22 6020938 02 6020938 02 Confidential technical information Viessmann Limited Hortonwood 30 Telfort Shropshire TF1 7YP GB Telephone 44 1951675000 Fax 44 1952 675040 E mail inf...

Отзывы: