59
Vitocal 060-A, type
WWK 060-A
WWKS 060-A
Draw-off profile
L
XL
*1
L
XL
*1
Electrical values
Max. power consumption
■
With immersion heater (accessory for
type WWKS; factory-fitted for type WWK)
kW
2.25
2.25
■
Without immersion heater
kW
—
0.75
Power consumption of the heat pump
kW
0.425
0.425
Power consumption of the immersion heater
(accessory for type WWKS; factory-fitted for
type WWK)
kW
1.5
1.5
Rated voltage (with and without immersion
heater)
1/N/PE 230 V/50 Hz 1/N/PE 230 V/50 Hz
Rated current
■
With immersion heater
A
9.8
9.8
■
Without immersion heater
A
1.84
1.84
MCB/fuse protection
A
16
16
Refrigerant circuit
Refrigerant
R134a
R134a
■
Refrigerant charge
kg
1.35
1.25
■
Global warming potential (GWP)
1430
1430
■
CO
2
equivalent
t
1.430
1.430
Permissible operating pressure
bar
MPa
25
2.5
25
2.5
Heating mode
Max. air flow rate, free-blowing
■
Speed 1 (slow)
m
3
/h
331
331
■
Speed 2 (fast)
m
3
/h
375
375
Integral DHW cylinder
Material
Enamelled steel
Enamelled steel
Capacity
l
254
251
Capacity of lower internal indirect coil
l
—
6.5
Max. permissible DHW temperature
°C
65
65
Max. permissible DHW temperature with im-
mersion heater
°C
65
65
Max. achievable DHW temperature in con-
junction with PV system
°C
62
62
Max. permiss. operating pressure
bar
10
10
MPa
1
1
Indirect coil
Indirect coil area
m
2
—
1
Capacity of lower internal indirect coil
l
—
6.5
Max. permiss. operating pressure
bar
—
6
MPa
—
0.6
Max. connectable aperture area, flat-plate
collectors
m
2
—
4.6
Max. connectable aperture area, tube col-
lectors
m
2
—
3
*1
Values determined by Viessmann
Specification
Specification
(cont.)
5788 057 GB
Appendix