17
Monday to Friday
■ 06:00 to 08:00 h and 16:00 to
22:00 h:
Central heating with standard room
temperature (Comfort 1)
■ 08:00 to 16:00 h and 22:00 to
06:00 h:
Central heating with reduced room
temperature
Saturday and Sunday
■ 07:00 to 23:00 h:
Central heating with standard room
temperature (Comfort 1)
■ 23:00 to 07:00 h:
Central heating with reduced room
temperature
Time program P3
Central heating in accordance with the
following time program:
Monday to Friday
■ 12:00 to 20:00 h:
Central heating with standard room
temperature (Comfort 1)
■ 20:00 to 12:00 h:
Central heating with reduced room
temperature
Saturday and Sunday
■ 07:00 to 22:00 h:
Central heating with standard room
temperature (Comfort 1)
■ 22:00 to 07:00 h:
Central heating with reduced room
temperature
Constant operating modes
You can set the following operating
modes:
■
"PERM COMFORT"
: Continuous
operation with standard room temper-
ature
■
"PERM REDUCED"
: Continuous
operation with reduced room temper-
ature
■
"FROST PROTECTION"
:
Frost protection mode:
– For room temperature-dependent
operation: At room temperatures
below + 6 °C.
– For weather-compensated opera-
tion: At outside temperatures below
+ 3 °C.
Commissioning
Time program or operating mode
(cont.)
5837779