![Viessmann H32E B300 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/viessmann/h32e-b300/h32e-b300_installation-and-service-instructions-manual_1017777013.webp)
13
A
B
C
D
E
Fig. 5
A
Ventilation unit
B
Condensate drain connector 1
¼
male thread
C
Waterless trap
D
Waste water pipe DN 40, e.g. HT pipe (on site)
E
Hose connection
7
18 to 20 mm
Trap with stench trap (on site)
60
A
B
C
D
Fig. 6
A
Ventilation unit
B
Condensate drain connector 1¼ male thread
C
Connection piece external diameter 32 mm (sup-
plied)
D
Trap with stench trap (on site)
Note
Secure pipe connections with PVC adhesive.
Electrical connections
Danger
Damaged wiring insulation can lead to serious
injury from electrical current and result in appli-
ance damage.
Route cables so that they cannot touch very hot,
vibrating or sharp-edged components.
Note
If 2 components are connected to the same terminal,
press both cores together in a
single
wire ferrule.
Installation sequence
Connecting the condensate drain
(cont.)
5816563
Installation