41
A
B
C
D
Fig. 32
A
ON/OFF switch for internal circulation pump and
control unit
B
Export meter Z2
C
Fuel cell module ON/OFF switch
D
ON/OFF switch at the fuel cell
1.
Close the gas shut-off valve.
2.
Switch ON/OFF switches
C
and
D
to ON.
Commissioning the system with the commissioning assistant
!
Please note
Only commission the appliance with a fully filled
trap.
Check that the trap has been filled with water.
Commissioning assistant
Fig. 33
1.
■
If the device has not been switched on yet:
Switch the ON/OFF switch to ON.
The commissioning assistant starts automati-
cally.
■
If the device has already been switched on: See
chapter "Calling up the commissioning assistant
at a later point".
2.
Select
"Language"
.
Commissioning, inspection, maintenance
Switching on the power supply for the fuel cell module
5839343
Содержание E00T