L
Temperature sensor at the heat
exchanger of the external unit
M
Compressor temperature sensor
N
Outside temperature sensor
O
Suction gas temperature sensors
at the EEV A, B, C
*
1
and D
P
Control PCB
R
Accessory connections
1 Night mode switch
2 Standby mode switch
3 Economy mode switch
4 Default mode switch (1 = heat-
ing, 0 = cooling)
5 Fault message output, max.
230 V~, 1 A
6 MegaTool (not available)
S
Programming unit PCB
T
Choke coil
U
Connection to the EMI filter PCB
(see page 46)
U
Connection to the power supply
PCB (see page 45)
V
EMI filter PCB
*
2
W
Power supply, 230 V~, 50 Hz
X
Connection with the internal
devices A, B, C
*
1
and D
External units
(cont.)
46
Connection and wiring diagrams
5692
689
GB
*1
Not applicable to type OT307H.
*2