Diagnosis at the internal device
In diagnostic mode, fault codes can be scanned individually for the internal
device and the external unit.
For a detailed description of the control and display elements, see the
operating instructions for the "Vitoclima-S".
Note
For the external unit from type OT307H, the diagnosis can be implemented
immediately at the external unit.
Activating diagnostic mode:
Hold down the "MODE" key at the
internal device (for duct mounted
devices at the receiver) for 5 to 10 s.
The diagnostic mode is acknowl-
edged by three short tones and the
illumination of the cooling and heating
LEDs.
Switching between the diagnosis of
the external unit and the diagnosis
of the internal device:
Every additional brief pressing of the
"MODE" key enables a changeover
between the internal device and the
external unit. This is acknowledged by
three short tones and the illumination
of the cooling and heating LEDs.
The remaining LEDs on the internal
device flash whilst the diagnosis of
the external unit progresses.
The remaining LEDs on the internal
device flash whilst the diagnosis of
the internal device progresses.
Fault codes are illustrated through the simultaneous illumination of the cooling
and heating LEDs.
The heating LED illuminates 5 times in succession. Either the cooling LED illu-
minates at the same time or not.
This results in the fault code detailed in the following table:
Note
Only one fault code will be displayed, even if several faults have occurred.
To display further fault codes:
&
Switch the unit OFF and isolate it from the power supply.
&
Remove the fault.
&
Call up the diagnostic function again.
Diagnosis
16
Troubleshooting
5692
689