69
■ Set the required parameters during
commissioning; see from page 83.
■ Connections, see separate "Connec-
tion and wiring diagram" sheet 40 to
sheet 192
Note
■ Plug F11: Nothing should be connec-
ted to plug F11 on site.
■ Flow temperature sensor for heat-
ing circuit with mixer (M3): The flow
temperature sensor for one heating
circuit with mixer (M3/HC3) is connec-
ted to the mixer extension kit (acces-
sories).
Sensors
Plug
Sensor
Type
F0
Outside temperature sensor; connect on site
Ni 500
(PTC)
F2
Primary circuit flow temperature sensor, connect on site
with 2-stage heat pump
Pt 500
(PTC)
F3
Primary circuit return temperature sensor, connect on
site with 2-stage heat pump
Pt 500
(PTC)
F4
Buffer temperature sensor, top; connect on site
Pt 500
(PTC)
F6
Cylinder temperature sensor, top; connect on site
Pt 500
(PTC)
F7
Cylinder temperature sensor, bottom; connect on site
Pt 500
(PTC)
F12
Flow temperature sensor, heating circuit with mixer (M2/
HC2); connect on site
Ni 500
(PTC)
F13
Flow temperature sensor, system (with sensor well,
downstream of heating water buffer cylinder); connect on
site
Pt 500
(PTC)
F14
Flow temperature sensor, cooling circuit (direct heating
circuit A1/HC1 or separate cooling circuit SKK); connect
on site
Ni 500
(PTC)
F16
Room temperature sensor for separate cooling circuit
(required) or for direct heating/cooling circuit (recommen-
ded); connect on site
Ni 500
(PTC)
F17
Never connect anything here
Pt 500
(PTC)
F18
Return temperature sensor, secondary circuit for heat
pump stage 2 (if installed), connect on site
Pt 500
(PTC)
F20
Boiler water temperature sensor, external heat genera-
tor; connect on site
Pt 500
(PTC)
Installation sequence
Overview of electrical connections
(cont.)
5848 164 GB
Installation