27
Commissioning steps
Inspection steps
Maintenance steps
Page
•
1. Removing the front panels
................................................................................................ 29
•
2. Filling the heating system
................................................................................................. 29
•
3. Filling the DHW cylinder on the DHW side
...................................................................... 30
•
4. Venting the boiler
............................................................................................................... 31
•
5. Filling the trap with water
.................................................................................................. 31
•
6. Venting the heating system
............................................................................................... 32
•
7. Commissioning the system
............................................................................................... 33
•
•
•
8. Checking all connections on the heating water and DHW sides for leaks
•
9. Designating heating circuits – only for weather-compensated control units
.............. 35
•
•
10. Checking the gas type
....................................................................................................... 35
•
11. Gas type conversion (only for operation with LPG)
....................................................... 36
•
•
•
12. Checking the static pressure and supply pressure
........................................................ 36
•
13. Function sequence and possible faults
........................................................................... 38
•
14. Setting the max. heating output
........................................................................................ 39
•
15. Activating screed drying
................................................................................................... 39
•
16. Tightness test on balanced flue system (annular gap check)
....................................... 40
•
17. Removing the burner
......................................................................................................... 41
•
•
18. Checking the burner gasket and burner gauze assembly
.............................................. 41
•
•
19. Checking and adjusting the ignition and ionisation electrodes
.................................... 43
•
20. Cleaning the heating surfaces
.......................................................................................... 43
•
21. Checking the condensate drain and cleaning the trap
................................................... 43
•
•
22. Installing the burner
........................................................................................................... 45
•
•
23. Checking the neutralising system (if installed)
•
24. Checking the anode connection and anode earth current with an anode tester
......... 45
•
25. Draining the boiler on the DHW side
................................................................................ 46
•
26. Cleaning the loading cylinder
........................................................................................... 47
•
27. Checking and replacing the magnesium anode (if required)
......................................... 47
•
28. Re-assembling and filling the loading cylinder
............................................................... 48
•
•
•
29. Checking the expansion vessel and system pressure
................................................... 48
•
30. Checking the pre-charge pressure and the DHW expansion vessel (if installed)
........ 49
•
•
•
31. Checking the safety valve function
•
•
•
32. Checking the firm seating of electrical connections
•
•
•
33. Checking all gas equipment for tightness at operating pressure
................................. 50
•
•
34. Checking the combustion quality
..................................................................................... 50
•
•
•
35. Checking the flue system for unrestricted flow and tightness
•
36. Matching the control unit to the heating system
............................................................ 51
•
37. Adjusting heating curves
.................................................................................................. 51
38. Connecting the control unit to the WLAN network
......................................................... 53
•
39. Connecting the control unit to the LON
........................................................................... 53
Commissioning, inspection, maintenance
Steps - commissioning, inspection and maintenance
5789 302 GB
Содержание B2TB
Страница 6: ...6 15 Keyword index 152 Index Index cont 5789 302 GB ...
Страница 12: ...12 1 4 2x 3 2 5 Fig 5 Installing the boiler Removing the front panels 5789 302 GB Installation ...
Страница 26: ...26 2 2x 4 1 5 3 Fig 19 Installing the boiler Fitting the front panels 5789 302 GB Installation ...
Страница 117: ...117 Parts lists Hydraulics 5789 302 GB Components ...
Страница 128: ...128 0008 0009 0004 0005 0006 0003 0002 0001 0007 Fig 75 Parts lists Miscellaneous 5789 302 GB Components ...
Страница 154: ...154 5789 302 GB ...
Страница 155: ...155 5789 302 GB ...