29
5680 011 -10
Viessmann AirflowPLUS AH2A Installation, Operating and Service
Stage 1 Heat
Stage 1 Cool
Fan Speed
24VAC
24VAC COM
Single stage thermostat
field supplied (typical)
Viessmann AirflowPLUS
Connection Board
Stage 2 Cool
Electrical
IMPORTANT
Thermostat
Most standard heat/cool, setback, or electronic thermostats
are compatible with the Viessmann AirflowPLUS AH2A
series air handlers.
Thermostat wire from the thermostat is connected to the
screw terminals located on the control board inside the
air handler. They should be connected as follows:
RH, RC – power (24VAC)
W – heating
Y – cooling (if present)
G – continuous run fan (if present on thermostat)
A/C condenser must be connected to position “AC relay
-Y-C” only. Improper connections will result in loss of
protection functions.
Installation
Note:
Before making the connection to the thermostat for
a two stage cooling function, remove the jumper
across terminals Y1 and Y2 on the Viessmann
AirflowPLUS connection board.
Note:
During continuous fan operation, the fan speed will
operate at 40% of the set cooling speed.