119
DHW
Parameter
Code
Delivered
condition
Commis-
sioning
Mainte-
nance/
Service
"Set DHW temperature"
6000
500 (
≙
50 °C)
"Min. DHW temperature"
6005
100 (
≙
10 °C)
"Max. DHW temperature"
6006
600 (
≙
60 °C)
"Hysteresis DHW temperature
heat pump"
6007
50 (
≙
5 K)
"Hysteresis DHW temperature
booster heater"
6008
100 (
≙
10 K)
"Start optimisation for DHW
heating"
6009
0
"Stop optimisation for DHW
heating"
600 A 0
"Set DHW temperature 2"
600C
600 (
≙
60 °C)
"Temperature sensor at bot-
tom of DHW cylinder"
600E
0
"Enable booster heaters for
DHW heating"
6014
0
"Enable electric heaters for
DHW heating"
6015
1
"Priority DHW heating with
combi cylinder"
6016
0
"Start attempts for DHW after
high pressure shutdown"
6017
1
"Cylinder primary pump ena-
ble"
601F
0
"Operating mode cylinder pri-
mary pump"
6020
0
Commissioning/service reports
Control parameters report
(cont.)
5546 267 GB
Service