background image

Vienybė EKO ex

 

   

Vienybė EKO ex

 

 

Vienybe EKO ex (17.01) EN

 

 

Vienybe EKO ex (17.01) EN

 

 

5

 

12

 

 

 

10.  Package contents

 

Fireplace 

1 pc.

 

Glove 

1 pc.

 

Installation manual 

1 pc.

 

Wooden pallet 

1 pc.

 

 

 

11. Warranty

 

Manufacturer guarantees that the fireplace complies with the requirements of LST EN 13240 and 

ГОСТ 

9817-95, provided that transportation, storage, installation and operation requirements were obeyed.

 

The fireplace is covered by a 24 month warranty; the beginning of the warranty period starts on the day 
of purchase.  For fire grates 6 month warranty is applied.

 

At the time of sale a salesman must inform a customer about the warranty terms and conditions, to fill in 
acceptance certificate and to deliver the installation manual.

 

During the warranty period manufacturer is obliged to rectify any defects free of charge, provided that 
they were caused by manufacturer's fault.

 

Warranty shall not apply in the following cases:

 

no purchase documents (a VAT invoice, a cashier's check or a cash order) are presented;

 

no acceptance certificate is presented;

 

the acceptance certificate is not completed or is completed incorrectly (the date of sale is not 

indicated, the shop stamp is not present, there is no serial number of the fireplace or the serial number 
does not match with the serial number indicated on the data plate on the fireplace);

 

installation and operation requirements are violated;

 

there is mechanical damage of the fireplace;

 

it has been determined that the fireplace was overheated (e.g., by using a wrong type of fuel);

 

it has been determined that the fireplace was repaired by unauthorized person;

 

acts of God;

 

the warranty does not apply to door glass and vermiculite plates. 

I have read and understand the warranty terms and conditions:

 

 

2.  Technical specifications

 

 

Name

 

Units

 

Value

 

Fuel used

 

 

Firewood

 

Maximum recommended measurements of firewood

 

mm

 

Ø90 x 250

 

Efficiency at nominal power

 

%

 

71,5

 

Nominal thermal power when heating with firewood

 

kW

 

8

 

Diameter of flue connection

 

mm

 

Ø130

 

Connection of flue from the top

 

 

Yes

 

Chimney draught at nominal power

 

Pa

 

12

 

Combustion chamber volume

 

dm

3

 

50

 

Average temperature of combustion products

 

°C 

340

 

Combustion gas flow

 

g/s

 

9

 

Area of heated premises

 

m

3

 

80

 

Burning time of the fuel load at nominal power *

 

h

 

0,7÷1,0

 

Fuel consumption

 

kg/h

 

2,5

 

Overall dimensions:

 

 

 

height

 

mm

 

913

 

width

 

mm

 

548

 

depth

 

mm

 

447

 

Weight, no more than

 

kg

 

113

 

* the time it takes for one load of fuel to burn completely depends on the type of fuel, humidity, 

amount of fuel in one load, and other factors.

 

 

 

The fireplace is designed for intermittent operation. Normally, a new load of fuel is loaded 
after the previous one has burned completely.

 

The fireplace must be used only with the door closed.

 

 

Surname of the customer, signature, and date

 

 

In case you run into any trouble during installation or use of the fireplace, please call 

+370 600 

022 80

.

 

 

In  case  you  have  any  claims  regarding  the  quality  of  the  product,  please  fill  in  an  application  for 
warranty  service and send it together with a copy of a purchase document by registered mail to the 
manufacturer: AB 

“Umega” dpt. “Vienybe”, Kauno str. 120, LT-20115, Ukmerge.

 

 

In case of an emergency please call the above-mentioned numbers or send an application for warranty 
service by fax +370 340 63544 or emai[email protected], and hand in the filled in and signed application 
and purchase document to company employees upon their arrival.

 

Содержание EKO ex

Страница 1: ...Instructions for installation and use Fireplace Stove Vienybė EKO ex ГОСТ 9817 95 Vienybė EKO ex 17 01 EN ...

Страница 2: ......

Страница 3: ...ion 6 4 Installation 7 4 1 Place of installation 7 4 2 Requirements for flue and chimney 8 Date of manufacture 5 Use 8 5 1 First heating 9 5 2 Heating 9 5 3 Ash cleaning 9 5 4 Fuel 9 6 Technical safety requirements 10 7 Maintenance 10 7 1 Glass cleaning 10 7 2 Interior and exterior cleaning 10 7 3 Replacement parts 10 8 Troubleshooting 11 9 Delivery and Storage 11 10 Package Contents 12 11 Warrant...

Страница 4: ...s manual Taking into consideration the foregoing I have a claim in respect of this product I believe that defects listed in the claim occurred due to imperfection of your product and hereby ask you to send your representatives in order to inspect the connected product to identify the defects and to rectify them Should there be determined that the abovementioned defects were caused by improper conn...

Страница 5: ...n acts of God the warranty does not apply to door glass and vermiculite plates I have read and understand the warranty terms and conditions 2 Technical specifications Name Units Value Fuel used Firewood Maximum recommended measurements of firewood mm Ø90 x 250 Efficiency at nominal power 71 5 Nominal thermal power when heating with firewood kW 8 Diameter of flue connection mm Ø130 Connection of fl...

Страница 6: ...ir supply is sufficient e g install an air vent turn off cooker hood Open air supply valve Clean the flue Remove ashes Unusually high amount of soot on the glass Firewood is too damp Large non split firewood is being used Wrong type of fuel is being used e g rubber plastic wood waste etc Wrong orientation of firewood Use firewood with up to 20 humidity Use split firewood of recommended size Use on...

Страница 7: ...TTENTION Use only original or recommended by the manufacturer replacement parts Use of non original replacement parts for repairs during the warranty period will void the warranty 4 Installation The fireplace shall be installed in premises that meet construction standards and requirements Installation and connection of the fireplace to a chimney shall be performed in accordance with Rules for inst...

Страница 8: ...y valve by pulling it towards yourself Put two average size pieces of firewood on the bottom of a combustion chamber leave a gap between those two pieces Put some crumpled newspaper or a solid fuel tablet in the gap then put some shredded and dry firewood in a crosswise manner and then some average size firewood on top Light up the paper and close the door when the paper starts to burn well A hand...

Отзывы: