For mounting, Viega recommends to use a Prevista Dry
fixing set.
Determine and mark the fixing points.
n
X1: 1100 mm
n
X2: 460 mm
Determine and mark the fixing points on the floor.
n
X3: 375 mm
Drill the holes.
Insert the dowels.
INFO! Mount the Prevista Dry fixing set pursuant to the instruc‐
tions for use for the fixing set.
Loosen the feet of the element using a fork spanner.
9
9
9
Handling
Prevista Dry washbasin element with individually adjustable ceramic height
19 from 38