Requirements:
n
The drain valve has been dismounted.
n
The flushing throttle has been removed.
Unlock the flushing throttle.
Set the flush flow at the throttle.
Lock the flushing throttle.
3.3
Cleaning and maintenance
The concealed cistern is constantly under mechanical, chemical, and
physical stress. For this reason, the components must be cleaned as
required, and the drain and filling valve seals renewed.
In areas or regions with hard water due to high concentration of calcium
or magnesium salts, there is the risk of limescale deposits developing
on the inlet and drain valves. The valves may have to be replaced,
depending on the extent of the deposits.
3.4
Disposal
Separate the product and packaging materials (e. g. paper, metal,
plastic or non-ferrous metals) and dispose of in accordance with valid
national legal requirements.
Setting the flush flow
Cleaning and maintenance of the concealed cistern
Handling
Prevista Dry WC element with shower WC connection
27 from 27