background image

for WC flush plates for Prevista
Model

8522

en_INT

Prevista Dry WC element with shower WC

connection

Instructions for Use

Содержание Prevista Dry 8521

Страница 1: ...for WC flush plates for Prevista Model 8522 en_INT Prevista Dry WC element with shower WC connection Instructions for Use...

Страница 2: ...Prevista Dry WC element with shower WC connection 2 from 27...

Страница 3: ...ents 7 2 4 3 Technical data 8 2 5 Accessories 9 3 Handling 10 3 1 Assembly information 10 3 1 1 Mounting conditions 10 3 1 2 Installation dimensions 11 3 2 Assembly 11 3 2 1 Mounting WC element 11 3 2...

Страница 4: ...d to possible operating instructions The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use 1 2 Labelling of notes Wa...

Страница 5: ...g DIN DVGW Some passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national regulations The relevant national la...

Страница 6: ...d even death Work on the electrics may only be carried out by trained electricians Switch off the mains voltage before carrying out work on electrical parts Switch off the mains voltage before connect...

Страница 7: ...9 Mounting set for WC ceramic 10 Flushing pipe 11 WC connection socket with lip seal 12 Site protection 13 Revision shaft cover 14 Corner valve 2 4 2 Compatible components The WC element is compatibl...

Страница 8: ...ion system is suitable for reducing odour nuisance in indoor bathrooms and highly frequented toilet facilities The odour extraction system is connected to the ventilation system directly An additional...

Страница 9: ...g directly onto the installation body or corner mounting on masonry or metal support profile Prevista Dry fixing set model 8573 for single mounting of Prevista Dry elements to the solid wall Prevista...

Страница 10: ...d The installation depth is maximum 200 mm The WC element can only be used in combination with wall hung WCs fixing gauges for bore hole 180 mm or 230 mm The WC element has an R inch water connection...

Страница 11: ...nry and concreted walls When mounting multiple WC elements with an interval of 500 mm Viega recommends the use of a Prevista Dry support bracket model 8570 48 Observe the instructions for use for the...

Страница 12: ...nd mark the fixing points on the floor n X3 375 mm Drill the holes Insert the dowels INFO Mount the Prevista Dry fixing set according to the instruc tions for use for the fixing set Loosen the feet of...

Страница 13: ...accordance with the on site marking of the upper edge of the finished floor n X 1000 mm Tighten the feet of the element using a fork spanner The element is attached to the wall 9 Handling Prevista Dry...

Страница 14: ...on the floor rail using the clips Set the height of the element by means of the feet Fix the element with the Prevista Dry Plus Steptec rail connectors Mounting in Prevista Dry Plus Handling Prevista...

Страница 15: ...The WC element is fixed in the Prevista Dry Plus pre wall con struction Handling Prevista Dry WC element with shower WC connection 15 from 27...

Страница 16: ...90 Screw the feet together with the support profile Adjust the construction height of the element in accordance with the on site marking of the upper edge of the finished floor n X 1000 mm Attach the...

Страница 17: ...If applicable connect further elements to the element via the sup port profile Handling Prevista Dry WC element with shower WC connection 17 from 27...

Страница 18: ...tion Remove the cover plate Place the press connector on the water inlet Press the connection Seal the threaded connectors of the corner valve Screw the corner valve into the thread side of the Stepte...

Страница 19: ...into the cistern INFO Ensure the corner valve is correctly seated Use the lock nut to screw the corner valve and the cistern to one another Remove the protective cap from the water supply hose Screw...

Страница 20: ...Turn the cover plate lock by 90 in a clockwise direction Place the revision shaft on the cover plate To remove the revision shaft press in the fixing clips at the side Handling Prevista Dry WC elemen...

Страница 21: ...bow Insert the mounting bracket for the drain elbow Insert the drain elbow to the desired depth Fasten the drain elbow using the bow Fit the site protection Handling Prevista Dry WC element with showe...

Страница 22: ...ians Switch off the mains voltage before carrying out work on electrical parts Switch off the mains voltage before connecting the power pack Lay the power supply for an electric flush plate up to the...

Страница 23: ...ole Counter the threaded rods in front of and after the element with a nut Place the protective caps on the threaded rods Corn the gypsum cardboard cladding panel at the revision shaft and at the site...

Страница 24: ...Clad the element with suitable gypsum cardboard cladding panels Handling Prevista Dry WC element with shower WC connection 24 from 27...

Страница 25: ...n is freely accessible n The water supply has been shut off n The ceramic has been mounted Fold the tabs forward Lift the drain valve Remove the drain valve through the revision opening Handling Previ...

Страница 26: ...Set the large flush volume at the drain valve Set the small flush volume at the drain valve Handling Prevista Dry WC element with shower WC connection 26 from 27...

Страница 27: ...lve seals renewed In areas or regions with hard water due to high concentration of calcium or magnesium salts there is the risk of limescale deposits developing on the inlet and drain valves The valve...

Отзывы: