Flow pres‐
sure
flush dura‐
tion
2 seconds
flush dura‐
tion
5 seconds
flush dura‐
tion
10 seconds
flush dura‐
tion
15 seconds
0.1 MPa
(1 bar)
0.5 l
0.9 l
2.2 l
3.5 l
0.2 MPa
(2 bar)
0.9 l
1.8 l
4.0 l
5.6 l
0.3 MPa
(3 bar)
1.0 l
2.2 l
4.5 l
6.8 l
0.4 MPa
(4 bar)
1.2 l
2.7 l
5.2 l
7.6 l
0.5 MPa
(5 bar)
1.3 l
2.9 l
5.7 l
9 l
Hygiene flushing
The setting determines if respectively how long after non-use a hygiene
flushing is actuated.
The following settings are possible:
n
function deactivated
n
Hygiene flush 1 hour after the last use
n
Hygiene flush 12 hours after the last use
n
Hygiene flush 24 hours after the last use (factory setting)
n
Hygiene flush 72 hours after the last use
n
Hygiene flush 168 hours after the last use
Product information
Urinal flush plate for Prevista Visign for More 200 infrared flush actuation
11 from 27