Position the drain unit on the double seal from below in such a posi-
tion that the upstand of the drain unit is placed in the recess of the
double seal.
Fit the valve top in the double seal.
Place the fixing screws in the drain unit and pull hand tight.
INFO! Cordless screwdrivers or similar tools can damage the
product. Only tighten the screws by hand.
3.2.3
Connecting overflow and drain
After the overflow and the drain have been mounted, you must connect
them both using the overflow pipe. Proceed as follows:
Requirements:
n
The overflow is mounted in the overflow opening.
n
The drain is securely mounted on the base of the bathtub.
NOTICE! Connections where the pipes are not inserted far
enough into each other become leaky. For this reason, maintain
a minimum insertion depth of 15 mm for every connection.
Handling
Rotaplex Drain/Overflow Functional Unit
12 from 16