3 Handling
3.1
Assembly information
3.1.1
Mounting conditions
The following requirements exist for the mounting of the drain / over-
flow:
n
The bathtub is installed.
n
The drainage line is installed all the way to the bathtub.
n
The underside of the bathtub is accessible.
3.1.2
Installation dimensions
Fig. 2: Dimensional drawing
The following values are valid for L (length) and H (height):
L = 150–680
H = 180–480
3.1.3
Required tools and materials
The following tools are required for mounting:
n
fine-toothed saw
n
slotted screwdriver
The following material must be purchased separately and must be avail-
able during mounting:
n
equipment set
Tool
Material
Handling
Rotaplex Drain/Overflow Functional Unit
10 from 16