background image

Model

Year built:

6142.33

from  06/2015

en_INT

Rotaplex Drain/Overflow Functional Unit

Instructions for Use

Содержание 6142.33

Страница 1: ...Model Year built 6142 33 from 06 2015 en_INT Rotaplex Drain Overflow Functional Unit Instructions for Use ...

Страница 2: ...Rotaplex Drain Overflow Functional Unit 2 from 16 ...

Страница 3: ...ssories 8 3 Handling 10 3 1 Assembly information 10 3 1 1 Mounting conditions 10 3 1 2 Installation dimensions 10 3 1 3 Required tools and materials 10 3 2 Assembly 11 3 2 1 Mounting overflow 11 3 2 2 Mounting the drain 11 3 2 3 Connecting overflow and drain 12 3 2 4 Connecting the wastewater system 13 3 2 5 Mounting equipment set 14 3 2 6 Leakage test 15 3 3 Control 15 3 4 Maintenance 16 3 5 Disp...

Страница 4: ...on does not extend to possible operating instructions The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use 1 2 Labelling of notes Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs DANGER This symbol warns against possible life threatening injury ...

Страница 5: ...r in Germany e g DIN DVGW Some passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national regulations The pertinent national laws stand ards regulations and guidelines as well as other technical guidelines have priority over German European guidelines in this manual The information is not binding for other coun...

Страница 6: ... trap for bathtubs with a 90 mm drain hole The drain overflow is suitable for extra long bathtubs Detailed information regarding all bathtub models and the corre sponding Viega drains overflows can be found in the catalogue or on the Internet An equipment set with rotatable rosette valve cone and cover plate must be purchased separately 2 2 Product description 2 2 1 Overview The following componen...

Страница 7: ...odour trap 10 pipe extension 11 overflow pipe 12 Bowden cable 13 sleeve 14 overflow unit 15 profile seal 16 O ring 17 fixing flange 2 2 2 Technical data Drainage capacity at an accumu lation height of 300 mm 1 25 l s Overflow capacity at an accumu lation height of 60 mm 0 63 l s Diameter of bathtub drain hole 90 mm Product information Rotaplex Drain Overflow Functional Unit 7 from 16 ...

Страница 8: ...st be purchased separately Equipment sets As this product is a the functional unit without rotatable rosette and valve cone you require an equipment set to enable complete mounting Equipment sets contain a rotatable rosette for the overflow and a valve cone for the drain of the functional unit You can find a choice of dif ferent models in various designs in the catalogue Equipment set Rotaplex Vis...

Страница 9: ...ion set It is possible to extend the odour trap below the bathtub in the case of bathtubs with a very thick floor The extension set model 6141 7 is available for such cases Optional accessories Product information Rotaplex Drain Overflow Functional Unit 9 from 16 ...

Страница 10: ...ub is accessible 3 1 2 Installation dimensions Fig 2 Dimensional drawing The following values are valid for L length and H height L 150 680 H 180 480 3 1 3 Required tools and materials The following tools are required for mounting n fine toothed saw n slotted screwdriver The following material must be purchased separately and must be avail able during mounting n equipment set Tool Material Handlin...

Страница 11: ...e O ring in the annular gap of the fixing flange Hold the overflow unit on the overflow opening of the bathtub from the outside Screw the fixing flange into the overflow unit by hand Pliers or other tools may damage the fixing flange Only turn the fixing flange by hand 3 2 2 Mounting the drain Proceed as follows to mount the drain Place the double seal into the drain opening of the bathtub Handlin...

Страница 12: ... the screws by hand 3 2 3 Connecting overflow and drain After the overflow and the drain have been mounted you must connect them both using the overflow pipe Proceed as follows Requirements n The overflow is mounted in the overflow opening n The drain is securely mounted on the base of the bathtub NOTICE Connections where the pipes are not inserted far enough into each other become leaky For this ...

Страница 13: ... top end of the overflow pipe into the rubber sleeve Maintain an insertion depth of at least 15 mm Push the union nut sliding ring and seal onto the bottom end of the drain elbow Screw the union nut on the drain unit 3 2 4 Connecting the wastewater system Proceed as follows to connect the drain overflow to the wastewater system Requirements n The overflow and drain units are installed on the batht...

Страница 14: ... must be purchased separately To avoid damage to the rosette and valve cone only mount the equip ment set after finishing all other work on the building site Proceed as follows Align and install rotatable rosette into the overflow unit Turn rotatable rosette to the right open position and hold Fit valve cone The pin on the underside of the valve cone must be led through the middle hole of the valv...

Страница 15: ...n the following drawing with particular care Check drain fitting for visible leaks 3 3 Control The drain overflow are controlled via rotatable rosette on the overflow Proceed as follows to open or close the drain Turn rotatable rosette to the left ð The drain closes itself INFO The valve cone sinks and prevents the water from draining away The cover plate does not alter its posi tion Handling Rota...

Страница 16: ...ng agent can be used for regular care and prevention of lime scale on the rotatable rosette and valve cone Under no circumstances should scouring agent or scratching objects be used Strong stains even around the drain unit and the siphon can be removed using typical household cleaner It should be noted that the cleaning agent should be rinsed off after the prescribed soaking time There should be n...