Status / description of problem
Solution
13
The Bluetooth connection is established.
—
14
The press machine is locked (usage lock).
Deactivate the usage lock using the app.
Use the On/Off button to switch the press machine on and off.
The press machine switches off automatically after ten
minutes if it is not used after switch-on.
Use the Start button to trigger a pressing; see
out the pressing process’ on page 24
.
The retaining bolt locks the press attachments in the press jaw fixture.
The retaining bolt is electronically monitored and must be fully inserted
to be able to start a pressing.
If a malfunction occurs and the press machine fails to complete the
pressing, press the Reset button to return the roller head to its initial
Chapter 3.6 ‘Aborting the pressing process’ on page 26
.
The press jaw fixture in the front part of the cylinder head can be
rotated 360° without a stop to allow for flexible alignment of the press
jaws to the pressing point.
The press machine is equipped with a bright LED lamp. The LED lamp
illuminates as soon as the Start button is pressed.
The press machine has two brackets, which can be used for example to
attach a shoulder strap.
On/Off button
Start button
Retaining bolt
Reset button
Rotatable cylinder head
LED light
Bracket
Product information
Pressgun 6 PlusPress machine with rechargeable battery and Bluetooth interface
20