3. END
Set the time to end the recording.
4. IPS (IMAGE PER SECOND)
NTSC
-
30
、
15
、
8
、
4
、
2
、
1
PAL
-
25
、
12
、
6
、
3
、
2
、
1
5. QUALITY
Select the quality of recording image: BEST, HIGH, NORM and BASE.
6. MODE
There are three recording mode settings :
QUAD-FRAME, QUAD-FIELD, MULTIPLEX.
NOTE: To select the appropriate recording mode before
you start recording. We don’t suggest to change
the different recording mode during the recording
to ensure the best recording quality.
7. TIMER ENABLE
When TIMER ENABLE is “YES”, press “menu” button, you
can see the timer diagram according to your setting.
(TIMER)
DAY START END IPS QLT MODE
DAILY 01:00 22:00 30 BEST Q-FR
OFF 00:00 00:00 30 BEST Q-FI
OFF 00:00 00:00 30 BEST Q-FI
OFF 00:00 00:00 30 BEST Q-FR
OFF 00:00 00:00 30 BEST Q-FR
OFF 00:00 00:00 30 BEST Q-FR
OFF 00:00 00:00 30 BEST MUX
OFF 00:00 00:00 30 BEST Q-FI
TIMER ENABLE : YES
12
CAMERA
1. TITLE
Assign a title to each camera. Initially each title is the camera’s number.
2. ALARM
Select LOW / OFF / HIGH for alarm polarity. The default value is LOW.
(MENU)
TIMER
CAMERA
RECORD
ALARM
DWELL
PIP
MOTION
DISPLAY
REMOTE
USER
SYSTEM
EVENT
TITLE
18
15
15
18
ON
HIGH
CAMERA04
18
15
15
18
OFF
HIGH
CAMERA03
18
15
15
18
OFF
OFF
CAMERA02
18
15
15
18
ON
LOW
CAMERA01
HUE
CL
CT
BR
REC
ALARM
(CAMERA)
3. REC (RECORD)
Set up which channel you want to record.
ON : when alarm input is triggered, DVR will record alarming channel more frequently.
For example : when CH01 is triggered, the record method will become 1-2-1-3-1-4….
OFF : DVR will not record.