219
for the following administrative states:
• Port-based 802.1X
• Single 802.1X
• Multi 802.1X
• MAC-based Auth.
Last Supplicant/Client Info
Name
IEEE Name
Description
MAC
Address
dot1xAuthLastEapolFrameSource The MAC address of the last supplicant/client.
VLAN ID
-
The VLAN ID on which the last frame from the last
supplicant/client was received.
Version
dot1xAuthLastEapolFrameVersion
802.1X-based:
The protocol version number carried in the most
recently received EAPOL frame.
MAC-based:
Not applicable.
Identity
-
802.1X-based:
The user name (supplicant identity) carried in the
most recently received Response Identity EAPOL
frame.
MAC-based:
Not applicable.
Selected
Counters
Selected Counters
The Selected Counters table is visible when the port is in one of the following administrative states:
• Multi 802.1X
• MAC-based Auth.
The table is identical to and is placed next to the Port Counters table, and will be empty if no MAC
address is currently selected. To populate the table, select one of the attached MAC Addresses from
the table below.
Attached
MAC
Addresses
Identity