background image

 
 
 

PAGE 3 of 8 

             VRDK1 TECHNICAL MANUAL 

 

VER1.0 

POWER SUPPLY 

 

Art.520M 

The power supply is the Art.520M. Outputs of 12Vdc (200mA), 8Vdc (300mA) and 13Vac 
(1A) are available. The dc outputs are designed to power the amplifier modules only and 
can not be used to power other devices such as lock releases etc. These items must be 
connected to the AC output of this power supply. 
 

 
 
 
 
 
 
 

 
 .

 

TELEPHONE 

 

Art.3021

 

 
 
 
 
 
 
 
 
 
 

 

BLOCK DIAGRAM 
 

 
 
 
 
 
 
 

 

INSTALLATION

 

 
The wiring diagram towards the back of this manual should be followed carefully. Heavy 
duty conductors on wiring diagrams are shown heavily outlined, These wires should be 
doubled up.  

 

-  Check that all components are free from damage before installing (Do not proceed with 

installation in the event of damage). 

-  Keep all packaging away from children. 
-  Do not obstruct the ventilation openings or slots on any of the devices. 

CONNECTIONS 

Terminal  Function 

+12 

 

12Vdc output (200mA Max.) 

+8 

 

8Vdc output (300mA Max.) 

-  

0V 

(Ground) 

 13Vac 

(1A 

Max.) 

 

 

 

230 

 

Mains in (Live connection) 

 

Mains in (Neutral connection) 

The Smart line Art.3021 is a wall mountable AC buzzer telephone 
and  includes a lock release push button.  

CONNECTIONS:- 

 Function 

Transmit speech to the door panel 

Receive speech from the door panel 

3 0V 

Not used (Electronic call tone input) 

Lock trigger (Switched 0V) 

Call  line (13Vac input to trigger buzzer) 

 

Fuse 
compartment 

Отзывы: