66251400-EN - V5.1 - 31/08/20
- 10 -
VK4K/6358 Series “6 wire Bus” videokit
VK4K/6358 Series - Installation handbook
PROGRAMMING TAGS (ONLY FOR ART. 4833X)
MASTER CARD
The module is supplied with a master card. The master card is preprogrammed in the factory.
The card is used to add and delete user access tags.
If the master card is lost, a new one will need to be created using the procedure detailed further on in this manual. In this instance,
it will be necessary to reprogram all the user tags. The module allows to store up to 30 user tags.
Note:
when the master card is required, place it in front of the reader so that the middle of the card is in front of the middle of the card name holder.
PROGRAMMING USERS TAG
The user tags can be programmed on the module using the master card to access the programming mode:
1. Place the master card in front of the tag reader.
Τ
The module emits one high-pitched
“beep”
sound and the
LED illuminates
BIP
2. Press the call button (the lower call button in the case of a 2-button external module) “n”
times where n is a value between 1 and 30 and specifies the tag number.
Τ
On each press the module emits a low-pitched
“beep”
sound and the
LED flashes.
BIP
Note:
the external module emits a low-pitched continuous
“beeping”
sound if an already pro-
grammed location is selected.
BIIIIIIP
3. When the desired memory location is reached the
LED starts flashing waiting for a tag.
4. Place the user tag to be programmed in front of the tag reader.
Τ
The module emits a low-pitched
“beep”
sound, the tag is programmed. The
LED
stops flashing and remains illuminated.
BIP
Note:
the module emits a low-pitched continuous
“beeping”
sound if an already programmed
location is selected.
BIIIIIIP
5. Repeat steps 2 to 4 for to program further tags.
6. To exit programming mode:
» Place the master key in front of the tag reader, or
» Wait 10 seconds.
Τ
The module emits two low-pitched
“beep”
sounds indicating it is back in normal
operating mode.
BIP BIP
USING TAGS
Place a tag in front of the tag reader:
Τ
If the tag is programmed, the external module emits two high-pitched
“beep”
sounds and
activates the relay. The
LED flashes twice and the
LED illuminates for the door open-
ing time.
BIP BIP
Τ
If the tag is not programmed, the external module emits two low-pitched
“beeping”
sounds.
BIIP BIIP
DELETING A SINGLE USER TAG
The master card is required to delete a user.
1. Place the master key in front of the tag reader.
Τ
The module emits one high-pitched
“beep”
sound and the
LED illuminates.
BIP
2. Press and hold the call button (the lower call button in the case of an external 2-button module).
Τ
The module emits a low-pitched
“beeping”
sound then after 1-2 seconds emits a high-
pitched
“beep”
sound and the
LED starts flashing, release the call button.
BIIP
BIP
3. Press the call button (the lower call button in the case of a 2-button external module) “n”
times where n is a value between 1 and 30 and specifies the memory location to delete.
Τ
On each press the module emits a low-pitched
“beep”
sound and the
LED stops
flashing.
BIP
4. When
the
LED restarts flashing, place the master card in front of the tag reader.
Τ
The module emits two high-pitched
“beep”
sounds then the module exits programming mode.
BIP BIP
DELETING ALL USER TAGS
The master card is required to delete all user tags together.
Art. 4833/4833X
Speaker unit
Содержание Videokit VK4K
Страница 25: ...66251400 EN V5 1 31 08 20 25...
Страница 26: ...66251400 EN V5 1 31 08 20 26...
Страница 27: ...66251400 EN V5 1 31 08 20 27...
Страница 28: ...66251400 EN V5 1 31 08 20 28...
Страница 29: ...66251400 EN V5 1 31 08 20 29...
Страница 30: ...66251400 EN V5 1 31 08 20 30...
Страница 31: ...66251400 EN V5 1 31 08 20 31...
Страница 32: ...66251400 EN V5 1 31 08 20 32...
Страница 33: ...66251400 EN V5 1 31 08 20 33...
Страница 34: ...66251400 EN V5 1 31 08 20 34...
Страница 35: ...66251400 EN V5 1 31 08 20 35...
Страница 36: ...66251400 EN V5 1 31 08 20 36...
Страница 37: ...66251400 EN V5 1 31 08 20 37...
Страница 38: ...66251400 EN V5 1 31 08 20 38...