background image

 
 
 

PAGE 6 of 24             AUDIO/VIDEO VANDAL RESISTANT TECHNICAL MANUAL 

 

VER1.1 

AUDIO SYSTEM POWER SUPPLY 

 

Art.520M 

The standard power supply is the Art.520M. Outputs of 12Vdc (200mA), 8Vdc (300mA) 
and 13Vac (1A) are available. The dc outputs are designed to power the amplifier modules 
only and can not be used to power other devices such as code locks, lock releases etc. 
These items must be connected to the AC output of this power supply. 
 

 
 
 
 
 
 
 
 

 

VIDEO SYSTEM POWER SUPPLY AND CONTROL UNIT 
 
Art.890

 

The 890 control unit is used on video systems. Its functions include call tone generation, 
voltage regulation and switching to both door panels and videophones, lock release control 
and camera recall. The Art.890 requires both 13Vac and 24Vac to operate. 

 .

 

CONNECTIONS 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

CONNECTIONS 

Terminal  Function 

+12 

 

12Vdc output (200mA Max.) 

+8 

 

8Vdc output (300mA Max.) 

-  

0V 

(Ground) 

 13Vac 

(1A 

Max.) 

 

 

 

230 

 

Mains in (Live connection) 

 

Mains in (Neutral connection) 

Terminal Function 

~ & ~ 

Power input 24Vac 

~

 & ~ 

Power input 13Vac 

 

 

Switched 20Vdc to videophones (Only on during a call) 

Switched negative from videophones to activate lock 

Receive speech from videophone 

Transmit speech to videophone 

Ground for speech circuits 

Ground for video circuits 

TV1 

Camera recall facility 

 

 

Electronic call tone output for call buttons 

13Vac output for ac lock release 

+8 

8Vdc output 200mA max. 

Ground for door panel speech circuits 

Push button commons for AC calling 

Switched 20Vdc for camera (Only on during a call) 

G2 

Receive speech from door panel 

H1 

Transmit speech to door panel 

F1 

Negative supply for camera unit 

F2 

Switched negative (Switches off when lock released) 

SE 

Switched negative to lock 

+12V 

12Vdc output 200mA max. 

 

 

V & M 

Coax in from camera (V=Centre core, M=Screen) 

V & M 

Coax out to videophones (V=centre core, M=Screen) 

For more information 
on the Art.890 please 
see the Videx Video 
technical manual 

Fuse 
compartment 

Содержание VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEM

Страница 1: ...TECHNICAL MANUAL EDITION 1 1 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS...

Страница 2: ...PAGE 2 of 24 AUDIO VIDEO VANDAL RESISTANT TECHNICAL MANUAL VER1 1...

Страница 3: ...system block diagram 14 Video system block diagram 15 Testing the installation 15 Panel care 15 Accessories connection guide 16 Single entrance single button audio wiring diagram 17 Single entrance mu...

Страница 4: ...ances SYSTEM COMPONENTS A standard audio system will comprise of a door panel power supply and audio telephones A standard video system will comprise of a door panel video controller power supply vide...

Страница 5: ...button video codelock 200mm W x 420mm H x 50mm D 1 BUTTON C 2 BUTTON B D Note Also available in 125mm 220mm panel style 3 BUTTON A C E 4 BUTTON B D G I 5 BUTTON A C E G I 6 BUTTON A C E F H J 7 BUTTON...

Страница 6: ...3Vac 1A Max 230 Mains in Live connection 0 Mains in Neutral connection Terminal Function Power input 24Vac Power input 13Vac 1 Switched 20Vdc to videophones Only on during a call 2 Switched negative f...

Страница 7: ...C 0V C 0V trigger input From 4V to 0V C volts trigger input From 8V up to 30V D Switched 20Vdc output via diode BST GMT digital time clock This time clock operates from a 12Vac or dc power supply The...

Страница 8: ...10 Centre core of coax to apartments 11 Screen of coax to apartments 12 Switched 20Vdc from Art 890 7A Transmit speech to door A 7B Transmit speech to door B 8A Receive speech from door A 8B Receive s...

Страница 9: ...anel 3 0V 4 Not used Electronic call tone input 5 Lock trigger Switched 0V 6 Call line 13Vac input to trigger buzzer 8 Dry contact switch 9 The Art 3102 AC buzzer telephone includes a lock release pus...

Страница 10: ...An Art 3980 back plate is required with this videophone CONNECTIONS Function 1 12V out to power video splitter 2 Camera recall 3 Spare button 4 20V power input 5 Door release command 6 Transmit speec...

Страница 11: ...en LED 14 Select input to switch on videophone 15 Call tone input 16 Common of spare buttons 17 Spare button 18 12V to power videophone privacy DIP SWITCH SETTINGS 8 Way dip switch Switches 1 5 Mute D...

Страница 12: ...e the mains Isolate the mains before carrying out any maintenance work on the system All intercom and access control cables must be routed separately from the mains Extension sounder for an apartment...

Страница 13: ...nals 1 2 6 10 and for terminals 3 5 3 Connections for power supply output to door panel and lock release connections 50m 100m Connections 0 5mm 0 75mm The power supply should be located as close to th...

Страница 14: ...5 8 0 35mm 0 35mm 0 5mm 0 75mm 1 0mm 6 9 0 35mm 0 5mm 1 0mm 1 5mm 2 0mm 7 10 0 35mm 0 35mm 0 5mm 0 75mm 1 0mm V 11 Standard quality Medium quality Good quality Good quality High quality M 12 75 Coax...

Страница 15: ...apartment speech in both directions video optional and lock release If the volume of speech needs to be adjusted this can be done by adjusting the presets on the rear of the amplifier at the door pane...

Страница 16: ...PAGE 16 of 24 AUDIO VIDEO VANDAL RESISTANT TECHNICAL MANUAL VER1 1 ACCESSORIES CONNECTION GUIDE 3101 3101 3101...

Страница 17: ...IDEO VANDAL RESISTANT TECHNICAL MANUAL VER1 1 WIRING DIAGRAM This diagram shows a single entrance vandal resistant door panel connected to two audio phones in the same apartment The lock release shown...

Страница 18: ...VER1 1 WIRING DIAGRAM This diagram shows a single entrance vandal resistant door panel connected to multiple apartments The lock release shown is fail secure 12Vac We suggest running all telephones b...

Страница 19: ...PAGE 19 of 24 AUDIO VIDEO VANDAL RESISTANT TECHNICAL MANUAL VER1 1 WIRING DIAGRAM This diagram shows a two entrance multiple apartments system 12Vac fail secure lock releases...

Страница 20: ...PAGE 20 of 24 AUDIO VIDEO VANDAL RESISTANT TECHNICAL MANUAL VER1 1 WIRING DIAGRAM This diagram shows a single entrance VR video door panel connected to a single apartment with two videophones...

Страница 21: ...PAGE 21 of 24 AUDIO VIDEO VANDAL RESISTANT TECHNICAL MANUAL VER1 1 WIRING DIAGRAM This diagram shows a two entrance system Two VR video door panels with two call buttons connected to two apartments...

Страница 22: ...terminal 1 on the door panel amplifier for continuity back to terminal 1 on the telephone Before lifting the handset check the voltage to on terminal 1 of the amplifier is 8 12Vdc Trace this voltage t...

Страница 23: ...with 12Vdc during a call Try taking the coax straight from the camera to a videophone Check for 20Vdc across the camera terminals I F1 during a call powered from Art890 Picture poor Check all end of l...

Страница 24: ...curity Ltd Unit 4 7 Chillingham Ind Est Newcastle Upon Tyne NE6 2XX TEL 0870 300 1240 FAX 0191 224 5678 Southern Office 1 Osprey Trinity Park Trinity Way London E4 8TD FAX 0208 523 5825 TECHNICAL SUPP...

Отзывы: