Instruc
tions manual - English - EN
43
MNVCUPTMAXB_1511_EN
10.1.5.1 Zone Titling Menu
This function allows setting up to eight (variable
dimension) areas with titling option.
It allows you to configure the following parameters:
Number:
Selects the area to be edited.
Enabling:
Enables the message linked to the related
zone to be displayed on the screen.
Start:
Sets the initial position of the area.
Stop:
Sets the final position of the area.
Text:
Modifies the text which is displayed when
moving within the zone.
ZONE TITLING
------------------------
1>NR. : 1
2 ENAB.: N
3 START: + 0.00
4 STOP : + 0.00
5 TEXT : ZONE 1
Fig.
93
Example:
To enable titling of zone 1 when the device
is b15° and +45°, it is necessary to:
• Enable area titling by setting Y as the value of
Enabling.
• Select 1 as value of parameter No.
• Set +015.00 as the value of parameter Start.
• Set the Stop parameter value to +045.00.
• If necessary, edit the displayed text by selecting
Text.
Setting the Start and Stop values of the
menu to zero will disable text display. If
there are overlapping areas, the area with
the lowest number will prevail.
Define the areas moving in a clockwise
direction, as shown in the figure.
0°
Start1=15°
Stop1=45°
Start2=170°
Stop2=225°
270°
90°
180°
Fig.
94