9 Switching on
Make sure that the unit and other
components of the installation are closed
so that it is impossible to come into contact
with live parts.
During normal operation the surface of the
illuminator can reach high temperatures.
Do not allow direct contact and position
the appliance where it is inaccessible to
unauthorised persons. Before touching
switch off the illuminator and allow to cool
for a minimum period of 10 minutes.
Do not stay in the vicinity of the device
when it is powered. Act on the device only
in the absence of a power supply.
Make sure that all parts are fastened down
firmly and safely.
The automatic pre-heating (De-Ice) process
could be started whenever the device is
switched on and the air temperature is
below 0°C. This process is used to ensure
that the device works properly even at
low temperatures. The duration ranges
depending on environmental conditions
(from 60 minutes up to 105 minutes).
The unit is switched on by connecting the power
supply.
To switch off the unit disconnect the power.
9.1 First start-up
The first time the device is switched on we
recommend making sure it is configured correctly.
Before providing power supply, remove the DIP
protection doors and position the firmware update
switch lever to ON (8.14.2 DIP1 configuration, page
34).
Power the device. After a few seconds, you can check
the configuration set on the monitor..
After completing the check, switch off the device and
re-toggle the firmware update switch rocker to the
down position.
Close the door and re-connect the power supply.
9.2 Checks list
Contact the assistance service if one of the
checks fails the test (ERR). The message OFF
means that the pan & tilt is not fitted with
the described option.
While it is switching on, the device displays a list of
the checks it has to carry out before starting normal
operation.
STARTUP
------------------------
TEST FLASH : OK
HOMING PROCEDURE : OK
ZFI SEARCH : OK
IO EXPANDER :OFF
IR360 STATE :OFF
Fig.
76