Pag. 13 SW42REM/SW82REM9904
Selection of alarm contact type
The programming of alarm contact type allows specifying for each of the 8 alarm inputs the normally open (NO) or
normally close (NC) condition.
•
Display contents: the display shows the type of contact (
NO/NC
) for each alarm and an
X
. The
X
means that the
corresponding input is displayed on the automatic channel.
•
Enter the parameters desired for each alarm, using the digital keys:
•
Key 1: moves to previous alarm
•
Key 2: moves to next alarm
•
Key 3: set the type of contact to
NO
for the alarm selected
•
Key 4: set the type of contact to
NC
for the alarm selected
•
Red key (for SWC4/SWC8, the
ENTER
key for DCMT8 keyboard) : displays/hides the
X
for the alarm selected
•
Move to
Selection of operating mode in case of alarm
entering the item
CONTINUE
and confirm
by
the red key
((for SWC4/SWC8, the
ENTER
key for DCMT8 keyboard).
In case of alarm, if the VCR trigger is activate, the switching on the automatic channel will display only the
inputs selected with X. If no X has been selected, the switching on the automatic channel will display only the inputs
alarmed.
Selection of operating mode in case of alarm
•
Configurate the parameters according to the following table using these keys
•
Key 1 : Goes back to previous item
•
Key 2 : Moves to next item
•
Key 3 and Key 4 : change the values for the item selected
•
Quit the programming by entering the item
END
and confirm by the red key (for SWC4/SWC8, the
ENTER
key for
DCMT8 keyboard)
Text displayed
Possible
values
Description
Memo /Autoreset
MEMO/AUTO
•
MEMO
: the alarm condition ends:
1. when the operator presses the AUTO key on the keyboard
2. when an external signal arrives at Pin 11 of ALARM
connector
3. after a certain period of time (see
Time Reset
function)
•
AUTO
: the alarm condition ends automatically when the alarm
signal stops
VCR Trigger
YES/NO
•
YES
: the VCR Trigger signal is connected to Pin 10 of ALARM
connector
•
NO
: the VCR Trigger signal is not connected to Pin 10 of ALARM
connector
Continuous Trigger
YES/NO
•
YES
: the VCR Trigger controls the automatic channel even without
alarm
•
NO
: the VCR Trigger controls the automatic channel only in
presence of alarm
External reset
YES/NO
•
YES
: the signal for alarm external reset is connected to Pin 11 of
ALARM connector
•
NO
: the signal for alarm external reset is not connected to Pin 11 of
ALARM connector
Switching time sec.
1..60
Enter the switching time for each video input if more alarms are present
at the same time.
Example
:
Entering 3
,
an alarm on channel 5 an one on channel 2
contemporarily display on the manual channel a 3-second switching
between inputs 5 and 2.
Reset from keyboard
YES/NO
•
YES
: an alarm can be stopped by pressing the keyboard AUTO key
•
NO
: it is not possible to stop an alarm from the keyboard
Time Reset
YES/NO
•
YES
: it is possible to stop automatically an alarm after a certain
period of time (5 sec. - 60 minutes)
•
NO
: it is not possible to stop an alarm after a certain time
after 5 min 0 sec
Specify the time interval related to the alarm
Time reset